Franklin Electric SubDrive Inline 1100 Owner's Manual

Franklin Electric SubDrive Inline 1100 Owner's Manual

Inline constant pressure system

Advertisement

BEFORE YOU START
BEFORE INSTALLING PUMP, BE SURE TO READ
THIS OWNER'S MANUAL CAREFULLY.
REFER TO PRODUCT DATA PLATE(S) FOR
ADDITIONAL OPERATING INSTRUCTIONS AND
SPECIFICATIONS.
C A U T I O N
Keep work area clean, well-lit and uncluttered.
Keep safety labels clean and in good condition.
Wear safety glasses while installing or performing
maintenance on pump.
Adhere to the guidelines of the National Electric Code
(NEC) or Canadian Electric Code (CEC), and any other
state and local codes for ALL electrical installations.
Check with the appropriate agencies or contact a
licensed electrician.
Adhere to the guidelines of national, state and local
plumbing codes when installing this product. Check with
the appropriate agencies or water system professional
for additional information.
Hazardous voltage.
Can shock, burn, or
Most water system problems result from improper
cause death.
installation. It is suggested that you read this manual
carefully before installing your pump.
Ground pump before
connecting to power
The "TROUBLESHOOTING SECTION" will assist you in
supply. Disconnect
locating and eliminating the cause of any trouble you
power before working
may encounter after installation. Check and make
on pump, motor
available all the tools you will need to install your pump.
or tank.
Required tooling may include wrenches, pipe sealant,
pipe fittings and nipples, screwdriver, etc. Be sure to
have available proper and adequate wiring material to
complete the installation correctly.
INLINE CONSTANT
PRESSURE SYSTEM
OWNER'S MANUAL
IMPORTANT INFORMATION FOR INSTALLERS
THIS EQUIPMENT IS INTENDED FOR INSTALLATION BY
TECHNICALLY QUALIFIED PERSONNEL. FAILURE TO INSTALL
IT IN COMPLIANCE WITH NATIONAL AND LOCAL
ELECTRICAL CODES, AND WITHIN FRANKLIN ELECTRIC
RECOMMENDATIONS, MAY RESULT IN ELECTRICAL SHOCK
OR FIRE HAZARD, UNSATISFACTORY PERFORMANCE, AND
EQUIPMENT FAILURE. FRANKLIN INSTALLATION
INFORMATION IS AVAILABLE FROM PUMP MANUFACTURERS
AND DISTRIBUTORS, AND DIRECTLY FROM FRANKLIN
ELECTRIC. CALL FRANKLIN TOLL FREE 800-348-2420 FOR
INFORMATION.
W A R N I N G
SERIOUS OR FATAL ELECTRICAL SHOCK MAY RESULT FROM
FAILURE TO CONNECT THE INLINE SYSTEM, METAL
PLUMBING, AND ALL OTHER METAL NEAR THE INLINE
SYSTEM OR CABLE, TO THE POWER SUPPLY GROUND
TERMINAL USING WIRE NO SMALLER THAN MOTOR CABLE
WIRES. TO REDUCE RISK OF ELECTRICAL SHOCK,
DISCONNECT POWER BEFORE WORKING ON OR AROUND
THE WATER SYSTEM. DO NOT USE INLINE SYSTEM IN
SWIMMING AREAS.
READ AND FOLLOW SAFETY INSTRUCTIONS
This is the safety alert symbol. When you see this
symbol on your pump or in this manual, look for one of
the following signal words and be alert to the potential
for personal injury:
D A N G E R
serious personal injury, death or major property damage
if ignored.
W A R N I N G
serious personal injury, death or major property damage
if ignored.
Hazardous voltage.
WA R N I N G
Can shock, burn, or
cause death.
Ground pump before
connecting to power
supply. Disconnect
power before working
on pump, motor
or tank.
C A U T I O N
cause minor personal injury or major property damage
if ignored.
ATTENTION!
OF THIS EQUIPMENT!
warns about hazards that will cause
warns about hazards that can cause
WA R N I N G
warns about hazards that will or can

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SubDrive Inline 1100 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Franklin Electric SubDrive Inline 1100

  • Page 1 THIS EQUIPMENT IS INTENDED FOR INSTALLATION BY TECHNICALLY QUALIFIED PERSONNEL. FAILURE TO INSTALL IT IN COMPLIANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES, AND WITHIN FRANKLIN ELECTRIC RECOMMENDATIONS, MAY RESULT IN ELECTRICAL SHOCK OR FIRE HAZARD, UNSATISFACTORY PERFORMANCE, AND EQUIPMENT FAILURE. FRANKLIN INSTALLATION...
  • Page 2: Package Includes

    Canadian Electric Code and local codes. • Pressure sensor and boot • Sensor adjustment tool GENERAL SAFETY • Installation manual The Franklin Electric Inline System is designed and built with a NEMA 4 approved drive enclosure to protect the pump’s electronic components.
  • Page 3: System Diagnostics

    CONSTANT PRESSURE INTRODUCTION as possible. Avoid using bends, elbows and fittings whenever possible. All suction connections must be The Franklin Electric Inline System provides consistent airtight, so use pipe compound on all threaded joints. water pressure regulation using advanced electronics to Use a suction strainer when applicable to prevent solids drive the pump/motor according to the system’s real-time...
  • Page 4 Do not operate pump unless pump is grounded. Refer to the included Inline System’s performance tables (Appendix 1) and friction loss tables (Appendix 2) to A fused disconnect switch or circuit breaker should determine the amount of head lost for a given application. be placed at or near the pump as required by local electrical codes.
  • Page 5: Typical Installation

    1.50" FIGURE 1: [ 38.1 ] 3.45" 10.43" [ 87.7 ] [ 265 ] ACCESS PANEL INPUT POWER ACCESS PANEL SCREWS 18.84" [ 478.5 ] 1-1/4" NPT 1-1/4" NPT SUCTION DISCHARGE 17.32" [ 439.9 ] TYPICAL INSTALLATION The Inline System is designed to both increase a system’s incoming pressure, and to provide the system with constant pressure across all outlets.
  • Page 6: Operation

    INSTALLATION PROCEDURE WIRING tightened to a torque of 10 in-lbs (1.13 Nm). 1. Disconnect electrical power at the main breaker. 10. Set the pressure tank pre-charge at 70% of the desired water pressure setting. To check the tank’s pre- 2. Verify that the dedicated branch circuit for the Inline charge, de-pressurize the water system by opening a tap.
  • Page 7 restrictions in the plumbing and will be more pronounced 6.) Slowly close the discharge valve until the cavitation is the farther the taps are from the pressure sensor. This no longer heard. would be true of any system, and if observed, should not 7.) The pump is now adjusted so that the system be interpreted as a failure in the performance of the Inline demand will not exceed what can be supplied.
  • Page 8: Maintenance

    mAINTENANCE LUBRICATION The pump requires only water for lubrication and must never be run dry. WA R N I N G W A R N I N G Before disconnecting pump, be sure fuse box leads are disconnected or power is turned off.
  • Page 9 REPLACEMENT PARTS - CONTINUED Spare Parts Kits for Inline 1100: FE Number Description Kit Grouping Identifier Repair Part Order Codes Drive Assembly 305707901 Mounting Posts Pump Motor Assembly 305707902 Mounting Feet 305707903 #10-24x1.625 Pan Head Torx #10 Lock Washer #10 Flat Washer #8-32x0.438 Pan Head Phillips Sealing #10-24x1.25 Flat Head Phillips Sealing 305707904...
  • Page 10: Troubleshooting

    TROUBLESHOOTING Green Steady - Pump is idle waiting for demand. Green Flashing - Pump is running Yellow Steady - Insufficient water supply Red Flashing - Service unit (See fault code) NUMBER OF FAULT POSSIBLE CAUSES CORRECTIVE ACTION FLASHES No water The pump is running dry check water source.
  • Page 11: Appendix 1 - Inline System Performance Curves

    APPENDIx 1 - INLINE SYSTEm PERFORmANCE CURvES Recommended Continuous Operating Range...
  • Page 12: Appendix 2 - Friction Loss Tables

    APPENDIx 2 - FRICTION LOSS TABLES Note: Chart shows friction loss per 100’ of pipe. To convert to friction loss per foot, move decimal point two places to the left. 1" 1-1/4" Schedule 40 pipe 1.380 in. i.d. / Type L Copper tube 1.265 in. i.d. Schedule 40 pipe 1.049 in.
  • Page 13: Limited Warranty

    THIS WARRANTY SETS FORTH THE COMPANY’S SOLE OBLIGATION AND PURCHASER’S EXCLUSIVE REMEDY FOR DEFECTIVE PRODUCT. Franklin Electric Company, Inc. and its subsidiaries (hereafter “the Company”) warrants that the products accompanied by this warranty are free from defects in material or workmanship of the Company.

Table of Contents