GENERAL INFORMATION

The Bullard ICE pump transfers ambient air from a clean air location,
where breathable air can be assured at all times, to workers wearing
Type C or CE continuous flow supplied air respirator hoods or tight
fitting half- or full-face masks.
The ambient air is filtered through a medium efficiency inlet air filter
and an inline 90 micron outlet filter before entering the respirator's
air supply hose.
Bullard ICE pumps are oil-less and have reciprocating pistons. They
produce no carbon monoxide, oil vapors, oil mist or moisture. They do
not require expensive carbon monoxide monitors, high temperature
alarms or airline filters. No calibration is required.

TABLE OF CONTENTS

General Information ......................................................................1
Warnings ............................................................................................2
Air Quality .........................................................................................3
Assembling the ICE Pump
Operating the ICE Pump ......................................................................4
Maintaining the ICE Pump ............................................................... 5-6
Replacement Parts ...............................................................................7
This Manual provides detailed instructions, warnings and other information for individuals using Bullard ICE Pump model.
ICE Pump
The chart below describes the number of respirators each unit will
supply and its maximum outlet pressure.
Pump Model No.
ICE PUMP
* Not recommended for respirator assemblies requiring a minimum of
60 psig to operate.
**To convert kPa to bar, divide kPa by 100
Maintenance Service Kits ....................................................................8
Assembly .............................................................................................9
Pump Warranty ..................................................................................10
Air Filter Replacement Schedule ...................................................... 11
www.bullard.com
User Manual
PUMP SPECIFICATION TABLE
Maximum Number of Respirators
Hood Style
Full or Half-
Mask
One
One
ICE Pump
Maximum
Air Pressure*
Approx. 60 psig
(400 kPa)**

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ICE and is the answer not in the manual?

Questions and answers

Summary of Contents for Bullard ICE

  • Page 1: Table Of Contents

    Assembling the ICE Pump Air Filter Replacement Schedule ............11 Operating the ICE Pump ..............4 Maintaining the ICE Pump ............... 5-6 Replacement Parts ................7 This Manual provides detailed instructions, warnings and other information for individuals using Bullard ICE Pump model. www.bullard.com...
  • Page 2: Warnings

    DO NOT use shutoff hoses with the ICE pump. Back pressure can damage pump when no respirator is connected. 5. DO NOT modify or alter this pump in any manner. Use only approved Bullard ICE pump components and replacement parts on the pump.
  • Page 3: Air Quality

    SERVICE FACTOR: 1.25 PROTECTOR: Internal Thermal Overload 2. Check to insure that the ICE pump has no visible damage. There is no other assembly required for the ICE pump. � WARNING 3. Check to be sure that the inlet filters, pressure gauge and outlet...
  • Page 4: Operating The Ice Pump

    WARNING service. The pump’s motor is equipped with a toggle switch and a 6 DO NOT USE SHUTOFF HOSES WITH THE ICE PUMP. BACK foot (1.8 m) grounded cord with a NEMA 5-20 three-prong plug. PRESSURE CAN DAMAGE PUMP WHEN NO RESPIRATOR IS For extension cords, 10 AWG (20 amps) or heavier duty gauge is CONNECTED.
  • Page 5: Maintaining The Ice Pump

    Initial Checklist the pump is continuously running. This heat is dissipated as it 1. You must use at least 100 feet of air supply hose for ICE Pumps, travels through the respirator’s air supply hose until it reaches per your respirator’s approved assembly. Any shorter length of ambient air temperature.
  • Page 6 3. Put a coiled section of the air supply hose in the bottom of a large container. Fill the container with water and ice and cover with a lid. For best results, locate the container as close to the worker as possible.
  • Page 7: Replacement Parts

    ICE Pump User Manual Replacement Parts List 8HDM SERIES REPLACEMENT PARTS AND ACCESSORIES FOR ICE PUMP DESCRIPTION 8HDM Cat. No. Description INLET FILTER ASSEMBLY 23611 23611 Inlet Filter FELT B344A ICEOF Inline Outlet Filter SAFETY VALVE AS100F V50IN Remote Inlet Air Hose Kit, 50 Feet (15 m) 1 per inlet...
  • Page 8: Maintenance Service Kits

    Bullard will not guarantee the performance of a field rebuilt pump. You can return the pump to a Bullard Authorized Service 2. Vent all airlines to the pump to remove pressure. You must vent all facility, or perform the rebuild procedures described.
  • Page 9: Assembly

    ICE Pump User Manual Assembly � WARNING 1. Install piston seals, piston rings, and rider rings on the piston. Disconnect electrical power supply cord before performing maintenance on this product. Some motors are thermally protected 2. Locate ring joints approximately opposite each other.
  • Page 10: Pump Warranty

    PUMP WARRANTY In no event shall Bullard be responsible for damages for loss of use or other indirect, incidental, consequential or special costs, expenses ICE PUMP ONE YEAR LIMITED WARRANTY or damages incurred by the purchaser, notwithstanding that Bullard has been advised of the possibility of such damages.
  • Page 11: Air Filter Replacement Schedule

    ICE Pump User Manual Air Filter Replacement Schedule The inlet filter keeps moisture as well as particulates out of the air supply. Regular inspection and replacement of the air filters will prevent We recommend the following chart be used to monitor and maintain a extensive and costly pump repair.
  • Page 12 Americas: Europe: Asia-Pacific: Bullard Bullard GmbH Bullard Asia Pacific Pte. Ltd. 1898 Safety Way Lilienthalstrasse 12 LHK Building ISO 9001 Cynthiana, KY 41031-9303 • USA 53424 Remagen • Germany 701, Sims Drive, #04-03 certified Toll-free within USA: 877-BULLARD (285-5273) Tel: +49-2642 999980 Singapore 387383 ©2015 Bullard.

Table of Contents