2.3 I Electrical connecti ons

• Only power on the appliance once all connecti ons (electrical and hydraulic) are complete.
• Using the supplied fi xture kit, install the control box on a rigid, verti cal surface in an easy-access locati on.
• Connect the power cord to a 230Vac mains outlet.
• Connect the stripped wire to couple the fi ltrati on pump to the fi ltrati on pump's 230Vac contactor using a
relay to avoid any voltage returns when the pump is stopped.