❷ Installation; I Selecting The Location; I Hydraulic Connections - Zodiac Red Line 3 Installation And User Manual

Table of Contents

Advertisement

❷ Installation

2.1 I Selecting the location

• The appliance must be installed in a dry ventilated plant room with no pool maintenance
products stored nearby.
• 90° elbow fittings must not be installed directly at the heater inlet and outlet; leave at least
25 cm of straight pipe to prevent chatter of the flow switch armature.
• The appliance must be positioned horizontally or vertically and held by piping supported by brackets on
either side of the heater,
• If the heater is installed in a vertical position, the direction of flow must occur upwards,
• Leave a free space around the appliance to facilitate its installation and maintenance,
• Preferably, the heater should be installed at the low point so that it is always full of water,
• The water treatment system must be installed at the low point after the heater to prevent chlorine from
flowing back into the heater.
• Comply with the direction of installation. If this is not complied with
(see diagram opposite), the flow switch will not be activated.

2.2 I Hydraulic connections

• An arrow on the heater body indicates the hydraulic connection direction to be implemented.
• The connection can be made using a PVC pressure pipe:
- directly if the flow rate is less than 30m³/h,
- via a by-pass if the flow rate is greater than 30m³/h,
- on the pool's filtration circuit, after the filter
• Check the correct clamping of the hydraulic connectors and that there are no leaks.
We recommend assembly with a by-pass since this facilitates appliance maintenance.
Hydraulic circuit pressure
Red Line
Test
3-6-9-12
4 bar
6
25 cm
25 cm
and before the water treatment system
Service
2 bar
Ø63 and Ø50
Minimum water
Connectors
flow
5 m³/h
V1-V2-V3: by-pass
valves
: Red Line
: Pump
: Filter
: Water treatment
.
Maximum
water flow
30 m³/h