Contemporary Research ICC-ZS2 Product Manual

Lg/zenith superport controllers
Hide thumbs Also See for ICC-ZS2:

Advertisement

Quick Links

Product Manual
ICC-ZS2
LG/Zenith SuperPort Controllers
Ver. 1.6 September 19, 2008
17630 Davenport Road, Suite 113 • Dallas, TX 75252
Phone:972-931-2728 • Toll-Free: 888-972-2728 • Fax: 972-931-2765
E-Mail:
Sales@crwww.com
• Website: www.crwww.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ICC-ZS2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Contemporary Research ICC-ZS2

  • Page 1 Product Manual ICC-ZS2 LG/Zenith SuperPort Controllers Ver. 1.6 September 19, 2008 17630 Davenport Road, Suite 113 • Dallas, TX 75252 Phone:972-931-2728 • Toll-Free: 888-972-2728 • Fax: 972-931-2765 E-Mail: Sales@crwww.com • Website: www.crwww.com...
  • Page 2: Table Of Contents

    RS-232 Responses ... 11 Response String Structure... 11 Command format: ... 11 iC-Net SmartZones... 13 System Map ... 14 Typical RF and ICC-Net Signal Flow ... 15 Safety Instructions ... 16 Limited Warranty and Disclaimer ... 17 Contemporary Research ICC-ZS2 Zenith SuperPort Card...
  • Page 3: Overview

    Contemporary Research offers the perfect solution for intelligent television control and interactive distributed media management, the ICC-series ZS2 LG/Zenith SuperPort Controllers. The ICC2-ZS2 communicates bi-directionally over the same RF coax that carries the CATV channels, while the ICC1-ZS2 receives commands over RF.
  • Page 4: Specifications

    Internal lug for TV GND wire Power: Powered by TV Options Internal buzzer for system alerts, closure for camera power relay (factory-installed options) IC-RC Wireless IR Remote for user control and system setup Contemporary Research -25 to +35 dBmV signal level ICC-ZS2 Zenith SuperPort Card...
  • Page 5: Installation

    ScanCards. 2. If you are installing the ICC-ZS2 in an existing TV that has a ScanCard, turn all four switches ON. 3. If the switches are set ON in a new TV, you will likely hear electronic noise in the audio.
  • Page 6: Using The Ic-Rc Remote For On-Screen Menus

    ICC2 unit’s RF output. Press Enter to stop transmitting, or the unit will automatically stop after 50 seconds. 65481 Display ICC2 transmitter frequency control voltage – should be 2000 - 3150. 65483 Display DF transmitter frequency deviation – should be 245 - 300. Contemporary Research Code ICC-ZS2 Zenith SuperPort Card...
  • Page 7: Rs-232 Control Protocol

    The unit or low order byte of the device (0 for global zone) <ncb> The number of command bytes to follow <cmd1> The first command byte <parameter> Command parameters (not used by all commands) [<cmdN>] Multiple commands can be concatenated, with byte count added to <ncb> Contemporary Research ICC-ZS2 Zenith SuperPort Card...
  • Page 8: Rs-232 Commands

    Bit 2 – Channel up/down operation, 0=Tune Ring, 1=Send IR Keypad response Bit 1 – Numeric channel labels, 0=num labels off, 1=num labels on) Bit 0 – Alpha channel labels, 0=alpha labels off, 1=alpha labels on 0 = Mute 0 = Blank video output to TV ICC-ZS2 Zenith SuperPort Card...
  • Page 9 MSB bit for the first channel; the next byte is the last. Selects IR remote and front panel control, except volume (0=enabled, 1=disabled) Selects volume control operation for IR and front panel (0=enabled, 1=disabled) Always 0 – Zenith does not differentiate between front panel and IR ICC-ZS2 Zenith SuperPort Card...
  • Page 10: Write Text

    Ex1: “$A5,<dh>,<dl>,10,‘DM’, 2,7,0,0,1,0,’TEST’ ” displays the word TEST on the second line, white text, inserted over video, small size with drop shadow, and timing out after 15 seconds. Ex2: “$A5,<dh>,<dl>,2,‘DM’ ” clears on-screen display, also clears persistent text Contemporary Research ICC-ZS2 Zenith SuperPort Card...
  • Page 11: Rs-232 Responses

    Sent when unit receives a new function command is pressed (1-8) or released (0) from the IR remote. 0 = Release 1 = Play 2 = Stop 3 = Pause 4 = Fast Forward 5 = Rewind 8 = Record Contemporary Research ICC-ZS2 Zenith SuperPort Card...
  • Page 12 HE will blink once per second. If the two numbers do not agree, the LED blinks twice per second. Contemporary Research 105 = Media Menu 106 = Cursor Right 107 = Cursor Left 108 = Cursor Up 109 = Cursor Down 110 = Media Select 116 = Timer ICC-ZS2 Zenith SuperPort Card...
  • Page 13: Ic-Net Smartzones

    6 would respond every time you sent a command to that one device. Contemporary Research Virtual Device 1023 1279 1024 1535 1280 1791 1536 2047 1792 2303 2048 2559 2304 2815 2560 3071 2816 3327 3072 3583 3328 3839 3584 4000 3840 4095 ICC-ZS2 Zenith SuperPort Card...
  • Page 14: System Map

    E154 1024 E251 1025 E252 1024 E253 1025 E254 1026 1280 G100 1281 G150 1282 G151 1283 1536 TV 1 1537 TV 2 1538 1792 1793 1794 1795 1796 2048 Admin 2049 A/V Center 2050 4095 ICC-ZS2 Zenith SuperPort Card...
  • Page 15: Typical Rf And Icc-Net Signal Flow

    Typical RF and ICC-Net Signal Flow The diagram below shows the structure of a typical Contemporary Research media retrieval system. One of the key aspects for iCC-Net communication is to provide a forward and return (sub-channel) path for data if you’re using ICC2 2-way TV Controllers.
  • Page 16: Safety Instructions

    Article 820-40 of the National Electrical Code (Section 54 of Canadian Electrical Code, Part I), that provides guidelines for proper grounding and, in particular, specifies that the cable ground shall be connected to the grounding system of the building as close to the point of cable entry as possible. Contemporary Research ICC-ZS2 Zenith SuperPort Card...
  • Page 17: Limited Warranty And Disclaimer

    Limited Warranty and Disclaimer Contemporary Research Corporation (CR) warrants this product to be free from defects in material and workmanship under normal use for a period of two years from the date of purchase from CR. Should such a defect occur CR will repair or replace, at their option, the defective product at no cost for parts or labor.

Table of Contents