Contemporary Research ICC-PRZ Product Manual

Smart tv controllers
Hide thumbs Also See for ICC-PRZ:

Advertisement

Quick Links

Product Manual
ICC-PRZ
Smart TV Controllers
Ver. 1.6 September 29, 2008
17630 Davenport Road, Suite 113 • Dallas, TX 75252
Phone:972-931-2728 • Toll-Free: 888-972-2728 • Fax: 972-931-2765
E-Mail:
Sales@crwww.com
• Website: www.crwww.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ICC-PRZ and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Contemporary Research ICC-PRZ

  • Page 1 Product Manual ICC-PRZ Smart TV Controllers Ver. 1.6 September 29, 2008 17630 Davenport Road, Suite 113 • Dallas, TX 75252 Phone:972-931-2728 • Toll-Free: 888-972-2728 • Fax: 972-931-2765 E-Mail: Sales@crwww.com • Website: www.crwww.com...
  • Page 2: Table Of Contents

    RS-232 Responses ... 12 Response String Structure... 12 iC-Net SmartZones... 14 System Map ... 15 Typical RF and ICC-Net Signal Flow ... 16 Mounting... 17 Safety Instructions ... 18 Limited Warranty and Disclaimer ... 19 Contemporary Research ICC-PRZ Smart TV Controllers...
  • Page 3: Overview

    ICC-series TV Controllers take advantage of Smart TV technology by Philips, RCA, and Zenith. Using the Smart TV data port, the TV Controllers use the TV’s internal IR sensor, character generator, and tuner to deliver cost- effective network TV and media management. The new S12 series can be update firmware via the RF coax through the ICC Head End.
  • Page 4: Specifications

    9 to 16.5 VDC, 12 VDC typical (may be unregulated) UL/CSA listed wall power supply included if needed for domestic shipments Contemporary Research ICC1-R RCA TV, 1-Way RF ICC2-R RCA TV, 2-Way RF ICC1-Z Zenith TV, 1-Way RF ICC2-Z Zenith TV, 2-Way RF ICC-PRZ Smart TV Controllers...
  • Page 5: Internal Closures

    Closure 2 - Pins 1 & 3 for dry contact to external power relay, AMX PC1 or similar Includes Smart TV data link cable Mounting hardware RF Loop Cable (ICC models only) 12 VDC Power Supply (Not included for international shipments or if powered by TV) Contemporary Research ICC-PRZ Smart TV Controllers...
  • Page 6: Installation

    3. The remote will now send the selected codes. 4. Remote will keep the codes, even if battery power is lost. IR Code Format Zenith Smart TV Philips Smart TV RCA Smart TV LG Smart LCD Contemporary Research Code ICC-PRZ Smart TV Controllers...
  • Page 7: On-Screen Setup Menus

    ICC2 unit’s RF output. Press Enter to stop transmitting, or the unit will automatically stop after 50 seconds. 65481 Display ICC2 transmitter frequency control voltage – should be 2000 - 3150. 65483 Display DF transmitter frequency deviation – should be 245 - 300. Contemporary Research ICC-PRZ Smart TV Controllers...
  • Page 8: Rs-232 Control Protocol

    Overview RS-232 control for up to 4000 TV Controllers is provided through an iC-series Head-End Network Controller. The ICC-HE Head-End manages iC-Net communication over RF Coax to ICC1 (1-way) and ICC2 (2-Way) TV Controllers as well as ICW TV Controllers over twisted-pair Cat3/5 wiring. The ICW-HE Head-End operates on the twisted-pair network only.
  • Page 9: Rs-232 Commands

    Same special-function channels as in the T Channel Select section above Select Q Channel “$A5,<dh>,<dl>,2,’QT’,<channel>” (7 bytes) – Tunes channel if included in TR Contemporary Research 0 = Mute 0 = Blank video output to TV ICC-PRZ Smart TV Controllers...
  • Page 10 Selects IR remote control operation, except vol. (0=enabled, 1=disabled) Selects volume control operation (0=enabled, 1=disabled) Always 0 Deletes Tune Ring in internal TV memory Always 0 Selects TV front panel buttons operation except vol (0=enabled, 1=disabled) ICC-PRZ Smart TV Controllers...
  • Page 11 Ex1: “$A5,<dh>,<dl>,10,‘DM’, 2,7,0,0,1,0,’TEST’ ” displays the word TEST on the second line, white text, inserted over video, small size with drop shadow, and timing out after 15 seconds. Ex2: “$A5,<dh>,<dl>,2,‘DM’ ” clears on-screen display, also clears persistent text Contemporary Research ICC-PRZ Smart TV Controllers...
  • Page 12: Rs-232 Responses

    Sent when unit receives a new function command is pressed (1-8) or released (0) from the IR remote. 0 = Release 1 = Play 2 = Stop 3 = Pause 4 = Fast Forward 5 = Rewind 8 = Record Contemporary Research ICC-PRZ Smart TV Controllers...
  • Page 13 HE will blink once per second. If the two numbers do not agree, the LED blinks twice per second. 105 = Media Menu 106 = Cursor Right 107 = Cursor Left 108 = Cursor Up 109 = Cursor Down 110 = Media Select 116 = Timer ICC-PRZ Smart TV Controllers...
  • Page 14: Ic-Net Smartzones

    You've probably figured out that you never want to assign a virtual device number to an actual device in the system. If you assigned #1536 to a device, all the TV controllers in Zone 6 would respond every time you sent a command to that one device.
  • Page 15: System Map

    One of the key tasks for iC-Net integrators is to create a logical System Map, assigning device numbers to TV controllers so they fall into logical zones. The device mapping could be sorted by type or location; whichever suits the application.
  • Page 16: Typical Rf And Icc-Net Signal Flow

    Typical RF and ICC-Net Signal Flow The diagram below shows the structure of a typical Contemporary Research media retrieval system. One of the key aspects for iCC-Net communication is to provide a forward and return (sub-channel) path for data if you’re using ICC2 2-way TV Controllers.
  • Page 17: Mounting

    Make sure you minimize blockage of any vent slots in the process hood. • Drill pilot holes (#36 0.106” or 7/64 0.109”), between 6 ¾ to 6 9/16 apart • Attach TV Controller using the two #6 self-tapping screws (included) Contemporary Research ICC-PRZ Smart TV Controllers...
  • Page 18: Safety Instructions

    Article 820-40 of the National Electrical Code (Section 54 of Canadian Electrical Code, Part I), that provides guidelines for proper grounding and, in particular, specifies that the cable ground shall be connected to the grounding system of the building as close to the point of cable entry as possible. Contemporary Research ICC-PRZ Smart TV Controllers...
  • Page 19: Limited Warranty And Disclaimer

    Limited Warranty and Disclaimer Contemporary Research Corporation (CR) warrants this product to be free from defects in material and workmanship under normal use for a period of two years from the date of purchase from CR. Should such a defect occur CR will repair or replace, at their option, the defective product at no cost for parts or labor.

Table of Contents