3.2 Description of available control options

3.2.1 DF control
General Description: Energy-saving hydraulic drives are
possible with pressure compensated pumps, especially in
combination with the loadsensing option.
Principle of function:
System pressure remains constant for the entire
volume flow rate. System pressure can be set manually,
hydraulically or electronically. The standard Hydrokraft
pressure compensator is pilot operated, has a remote port
and is very stable.
Maximum pump flow can be limited mechanically to
between 50% and 100% by a screw.
Circuit shown is just an example, other options available. For circuit of individual pumps please contact technical support
8
HYDROKRAFT OPERATION MANUAL PVW 250+360 E-PUIO_II001-E April 2021 www.eaton.com
A DF controlled pump can be combined with
following options:
Pilot operated by proportional valve (with el. card or
with on board electronis)
Pilot operated via remote port only option
Additional option for slow upstroke adjustment screw
for each of above options
Power control
Flow control
A
– System port
B
– Inlet port
L1, L2 – Drain port
L3
– Vent port for vertical mounting
L3.1, L8 – Air bleed port
L5
– Oil filling plug
MA
– Gauge port, system pressure
ML
– Gauge port, case pressure
X1
– Remote port pressure
compensator
1
– Basic pump
2
– Connection plate for DF-control
3
– Pressure compensator,
main stage
4
– Pressure compensator,
pilot stage