BLUEHELIX TECH RRT 28 C
Replacing the main exchanger
3
1
•
Drain the boiler heating circuit water
•
Extract the flue connection (concentric or accessory for separate ducts)
•
Remove the fan
•
Remove the clips of the two pipes on the exchanger, pump and hydraulic unit
•
Remove the 2 top screws "5" securing the exchanger to the frame (fig. 39)
•
Loosen the 2 bottom screws "5" securing the exchanger to the frame (fig. 39)
•
Remove the exchanger
•
Insert the new exchanger, resting it on the bottom screws "5".
•
For assembly, proceed in reverse order
EN
4
1
2
1
2
fig. 39- Main exchanger
cod. 3541N260 - Rev. 01 - 10/2017
1
5
5
6
5
5