TESTING AND CONFIGURING

Configure the Solar Box and make sure the option MODE is set to SOLAR. Also
make sure the menu option MAINSMET is set to SENSORBOX. After exiting the
menu, the measured currents should be visible on the display.
From top to bottom the display shows the measured values for L1, L2 and L3. A
minus indicates that the power at that phase is delivered to the grid.
When using the CT's, it's possible that the measured currents are not displayed
correctly. If there are negative values shown, while not feeding back to the grid,
the voltage input plug (MAINS) on the sensorbox should be reversed.
In case of deviating values, check the order of the CT connections on the
sensorbox. The value of L1 must be displayed correctly, if the voltage input is also
connected to the same phase.
If necessary, swapping the CT's on connection 2 and 3 should be sufficient to get
everything right.

SPECIFICATIONS

Charging System
Cable version car connector
Outlet version
Power input
Power output
Earth leakage protection
Dimensions
Housing
Weight
Environment Operating
Temperature
Marking
www.ratio.nl
www.ratio.nl
IEC61851, Mode 3
IEC 62196, type 1 or type 2
IEC 62196, type 2 Outlet
single-phase or 3 phase, 230V-400V, 16A-32A
3,7 kW, 7,4 kW, 11 kW, 22 kW
AC 30mA, DC 6mA
400mm x 250mm x 105mm
PC/ABS-VO
4 kg (incl. cable)
IP54, rain-tight
-25°C to +40°C
CE