Disassembly Of Tpu Unit - Epson Stylus PHOTO RX640 Service Manual

Hide thumbs Also See for Stylus PHOTO RX640:
Table of Contents

Advertisement

EPSON Stylus PHOTO RX640/650

4.4.5 Disassembly of TPU Unit

1.
Remove the Scanner Unit (p.45)
2.
Remove the TPU Unit while pushing the hook (middle) in the hinge area of the
TPU Unit. (Fig. 4-46)
3.
Remove the screws (x4) securing the TPU Cover. (Fig. 4-47)
4.
Lift the threaded hole side of the Harness Cover slightly, and remove the cover by
sliding it toward the front.
5.
Remove the Film Holder.
6.
Release the right and left hooks (3x2), and remove the TPU Cover.
When installing the TPU Cover, engage the hooks (x4) in the
front first and then engage the right and left hooks (x3).
When installing the Harness Cover, insert the Harness Clamp
area in the position shown below first and then slide the cover
from the front side into its position.
(éüÇÃÉyÅ[ÉWÇ÷ë±Ç¦)
Disassembly and Assembly
Harness Cover
Disassembly of Scanner Unit
Hook
Figure 4-46. Removing the TPU Unit
Lift it slightly and pull it
toward you
2
3
C.B.P-TITE 2.5x10 (x4)
·
Torque : 0.6±0.1N
m
Figure 4-47. Removing the TPU Cover
Revision A
Hinge area
Harness Cover
4
1
Hooks
59