Vibra CUX Series Quick Start Manual

Vibra CUX Series Quick Start Manual

Counting scale

Advertisement

An intelligent counting scale with perfect accuracy and usability
The full lineup of products comes equipped with excellent features and the pioneering spirit of counting scales, 
made to be easy to use, accurate, and robust.
Variation Guide
Displays distinction
results of the
limit function
AISCS Function
Restore function
that improves
counting accuracy
-0.5pcs.
+0.5pcs.
Variation Guide
ACR Function
Tare Skip Prevention Function
NEW
CUX Series New Function
Tare Skip Prevention
Function in operation
SHINKO DENSHI CO., LTD.
SHINKO DENSHI CO., LTD.
3-9-11 YUSHIMA, BUNKYO-KU, TOKYO 113-0034
TEL : 81-3-3831-9656 FAX : 81-3-5818-6066
URL : http://www.vibra.co.jp/global/
E-mail : shinko-denshi@vibra.co.jp
www.facebook.com/VIBRAbalance
Displays total weight
Displays weight per unit for sampling
300 item memory function
Registers 300 items to memory.
Registers up to 30 of these in combination with
tare weight.
Counting Limit Function
Set maximum and minimum values to distinguish
measurement results with  Hi (high) , 
Ok (proper quantity) , and  Lo (low) .
Accumulative adding function
Calculates the accumulative total by adding each
time after doing sub-division work.
Total and accumulative total are displayed
simultaneously, making them easy to see.
Counting Setting Function
Saves quantities with any number. 
CR function operation ON.
Unit Weight Setting
Saves unit weight with any number.
ACR (Automatic Counting Revision Function)
If data stabilizes when the variation fraction (−0.5 pcs. to +0.5 pcs.) is 
in the safe range, then the CR function can work automatically (ACR 
function) to do counting work accurately.
It is also possible to turn the ACR function OFF so it can be used to 
detect contaminants being mixed in.
Tare Skip Prevention Function Mechanism
1
Counting
2
Remove the containers
3
Screen display
Tare Skip Prevention Function in operation
4
Cannot count quantity until you press the taring button
Distributed by:
1804-000
Counting Scale CUX Series
SHINKO DENSHI CO., LTD.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CUX Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vibra CUX Series

  • Page 1 An intelligent counting scale with perfect accuracy and usability The full lineup of products comes equipped with excellent features and the pioneering spirit of counting scales,  made to be easy to use, accurate, and robust. Displays total weight Displays weight per unit for sampling 300 item memory function Registers 300 items to memory. Variation Guide Registers up to 30 of these in combination with tare weight. Displays distinction Counting Limit Function results of the Set maximum and minimum values to distinguish limit function measurement results with  Hi (high) ,  Counting Scale CUX Series Ok (proper quantity) , and  Lo (low) . Accumulative adding function Calculates the accumulative total by adding each time after doing sub-division work. Total and accumulative total are displayed AISCS Function simultaneously, making them easy to see. Restore function Counting Setting Function that improves Saves quantities with any number.  counting accuracy CR function operation ON. Unit Weight Setting Saves unit weight with any number.
  • Page 2 Counting Scale Capacity : 60g 〜 150kg / Minimum readability : 0.001g 〜 20g / Countable Unit Weight : 0.1mg 〜 1.5g Back-light LCD display series CUX series  Counting Scale Tuning Fork Sensor Strain Gauge Sensor This scale realizes a counting error of “zero”...

This manual is also suitable for:

Cux60Cux150Cux300Cux600Cux1500Cux3000 ... Show all

Table of Contents