Compressor Operation - Eastwood QST-80 Instructions Manual

Scroll compressor
Table of Contents

Advertisement

As an added precaution, the following check should be performed before starting the Compressor for the first time:
1. Obtain the assistance of an observer and view the Motor cooling fan blades visible through the screened housing at the end of the Motor case (FIG 10).
2. Have the same observer note the directional arrow label on the Motor case (FIG 10).
3. Depress the "START" Button
4. If the observer views the cooling fan begin to rotate in the opposite direction of the directional arrow label, depress the "OFF" Button
5. If 3 phase connection corrections are required, do so and repeat check sequence beginning at step 1.
6. If correct rotation of the Motor has been verified, proceed to COMPRESSOR OPERATION.
FIG. 10

COMPRESSOR OPERATION

• Depress the "START" Button
• Allow the Tank pressure to build to 145 PSI [10 bar] before each use. With the Air Compressor turned on, operation is automatic and under the control of
the internal Pressure Controller. It will turn off @ 145 PSI [10 bar] and automatically restart @ 115 PSI [8 bar].
The Pressure Gauge is visible through the upper right-side Compressor Panel and indicates the actual output line and tank pressure.
When the pressure reaches the 145 PSI [10 bar] cutoff point, an Unloader Valve will automatically release static pressure in the
Scroll to allow it to easily restart without needing to overcome residual pressure. This produces a momentary audible "hiss" or
"burbling" sound and is normal.
To order parts and supplies: 800.343.9353 >> eastwood.com
of the Control Panel.
Indicator Arrow
Fan rotation
of the Control Panel (FIG 9).
FIG. 11
Black
immediately!
White
Red
Ground
9