AIR LINE CONNECTION
The Eastwood QST 30/60 Compressor is designed with a high efficiency, 1/2" Ball Valve at the air outlet with 1/2" FNPT threads.
It is strongly recommended to use 1/2" or larger air lines and fittings throughout your system. The use of 3/8" or smaller lines is
acceptable but will greatly hamper performance.
It is strongly advisable to use a suitable high efficiency Air Regulator and Moisture/Oil Separator in a well-planned air-line layout after the Air Outlet Valve.

COMPRESSOR OPERATION

• Close the Water Drain Valve located at the underside of the Tank (FIG 10).
• Move the Power Switch to the "ON" position (FIG 12).
• Allow the Tank pressure to build to 145 PSI [10 bar] before each use. With
the Air Compressor turned on, operation is automatic and under the control
of the internal Pressure Controller. It will turn off @ 145 PSI [10 bar] and
automatically restart @ 115 PSI [7.9 bar].
The Pressure Gauge, located on the side of the "ON/OFF"
and Pressure Switch, indicates actual tank pressure
(Fig 13).
8
FIG. 12
OFF
FIG. 13
Gauge
Open
Close
Eastwood Technical Assistance: 800.343.9353 >> techelp@eastwood.com
ON
Pressure
Relief