Packet With Data About State Changes Of The Outputs Out_1 Or Out_2; Packet With Time Correction Request; Settings Packet - Vega Absolute M-BUS-1 User Manual

Lorawan converter
Hide thumbs Also See for M-BUS-1:
Table of Contents

Advertisement

M-BUS-1 / User Manual
1 byte
Battery charge, %
1 byte
Values of basic settings (bit field)
1 byte
Input number on which "Alarm" is noticed (1 or 2)
1 byte
Input 1 state («0» - unlocking, «1» - closure)
1 byte
Input 2 state («0» - unlocking, «1» - closure)

5. Packet with data about state changes of the outputs OUT_1 or OUT_2

Data sent on LoRaWAN port 2.
Size in bytes
Field description
1 byte
Packet type, this packet == 6
1 byte
Battery charge, %
1 byte
Values of basic settings (bit field)
1 byte
Output number on which change is noticed (1 или 2)
1 byte
Output state («0» - off, «1» - on)

6. Packet with time correction request

Sent every seven days on LoRaWAN port 4.
Size in bytes
Field description
1 byte
Packet type, this packet == 255
4 bytes
Time of the modem at moment of the packet transmission
(unixtime UTC)
After receiving this type of package, the application can send to modem the packet with
time correction.

7. Settings packet

Sent on LoRaWAN port 3.
Size in bytes
Field description
1 byte
Packet type, this packet == 0
2 bytes
ID of parameter
1 byte
Data length (len)
len bytes
Parameter value
2 bytes
ID of parameter
1 byte
Data length (len)
len bytes
Parameter value
...
...
2 bytes
ID of parameter
1 byte
Data length (len)
len bytes
Parameter value
Revision 15 – 30 June 2021
uint8
uint8
uint8
uint8
uint8
Data type
uint8
uint8
uint8
uint8
uint8
Data type
uint8
uint32
Data type
uint8
uint16
uint8
-----
uint16
uint8
-----
...
uint16
uint8
-----