Time Setting; Advanced Options - C-LOGIC 420-TC Instruction Manual

Digital programmable thermostat by radio frequency
Table of Contents

Advertisement

Available languages

Available languages

Program P3:
P3 is a pre-set program with different intervals for workdays (Monday to Friday) and weekends
(Saturday and Sunday). 4 intervals are defined for workdays and 2 intervals for weekend. It is not
possible to change intervals or temperatures. The setting is as indicated below:
Day of the week
Workday
Weekend

Time setting

In the setting screen, rotate the rotary key to choose
setting screen.
Firstly, minutes are flashing. Rotate the rotary key to adjust the minute value and press the key to
confirm.
Then, hours are flashing. Rotate the rotary key to adjust the hour value and press the key to confirm.
Finally weekday is flashing. Rotate the rotary key to select the current weekday and press the key to
confirm and return to the setting screen. After 5 seconds, it automatically returns to the main screen.

Advanced options

In the setting screen, rotate the rotary key to choose the
advanced option screen. The parameters indicated below will be displayed consecutively. Modify the
value rotating the rotary key and press the key to confirm and jump to the next parameter.
Symbol
Description
Measured
A1
temperature
adjustment
Temperature
A2
hysteresis
A3
Lock function
Automatic
A4
option
High measured
A5
temperature
value
Low measured
A6
temperature
value
Period
1
2
3
4
1
ADVANCED
PROG
TIME
Parameter setting
-9-+9 ºC
0: Half lock
1: Full lock
--: no automatic programs
01: automatic programs
35 ºC-70 ºC
5 ºC-10 ºC
12
Interval
22:00—6:00
6:00—8:00
8 00—16:00
16:00—22:00
6:00-22:00
22:00-6:00
icon and press the key to enter into time
icon and press the key to enter in the
ADVANCED
PROG
TIME
1-9 ºC
Temperature
17ºC
21ºC
17ºC
21ºC
21ºC
17ºC
Default
value
0.0
0.5
0
01
35
5

Advertisement