Key Operation; Main Setting Screen - C-LOGIC 420-TC Instruction Manual

Digital programmable thermostat by radio frequency
Table of Contents

Advertisement

Available languages

Available languages

Key operation

No.
Symbol
A
Rotary button
B
Rotary button
C
Rotary button
D

Main setting screen

Modo
Explicación
Automátic
Una pulsación corta de la tecla
mode
icono
Other short press of the rotary button enables the manual mode, displaying the
the button clockwise (increasing the temperature) or anticlockwise (decreasing
the temperature). When room temperature is lower than setting temperature,
Manual mode
the heating contact will be closed and the cooling contact will be opened (
is displayed) and when room temperature is higher than setting temperature,
the heating contact will be opened and the cooling contact will be closed (
disappear)
Under automatic mode and unlock state, when rotating the button to adjust the
temperature, it will enter into temporary manual mode. This temporary mode
Temporary
works to next interval when it will return to the automatic mode. If you want
manual mode
to return to automatic or manual mode, please press the button once or twice
respectively.
Press the rotary button
select the required icon and press the button to confi rm the access to that setting.
Holidays
After entering into setting screen, rotate rotary button to select
mode
press the key to enter into holiday mode setting. Select ON in order to enable
the holiday mode. Then adjust the number of days (countdown until returning to
automatic mode) by rotating again the rotary key and press the key to confi rm.
Finally and exit to the main screen. To cancel the holiday mode return the holiday
mode setting, select OFF and press the key to confi rm.
Description
Clockwise rotation for increasing the value
1.
Under turn on state, a short press switches between manual and
automatic mode.
2.
Under turn on state, a long press (3 seconds) allows to enter in the
setting screen.
3.
In other screens, it acts as confi rm key.
Anticlockwise rotation for decreasing the value
Short press for power on / off.
Long press (3 seconds) for screen locking or unlocking.
en pantalla.
icon. Under this mode, it is possible to adjust the set temperature by rotating
for 3 second for entering in the setting screen. Rotates the button to
activará el modo automático, mostrando el
10
icon
will
icon and

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clogic420tc230vcbint

Table of Contents