Use and maintenance
Operating guidelines AS4325B
Turn on the machine and verify there is
enough battery power to complete the
work. Charge batteries if required.
With the machine on, press one of the safety switches to engage the brush/pad-holder, then
release it. If necessary, repeat the procedure until the brushes/pad-holder is engaged.
The squeegee is raised and lowered with the deck.
Check the solution level the red ball on the
left side of the machine.
Lift the squeegee up by hand until it locks in
up position and turn suction off for double
scrubbing. To go back to working mode,
use the red lever to release the squeegee.
and turn suction on again.
July 2020
Lift the deck by pressing the pedal
Start cleaning by placing the hands on the
safety switches
When scrubbing is complete, turn off
the machine to perform the following
maintenance
Place the brush or the pad-holder under the
deck and Lower the deck or the brush/pad-
holder by pressing the pedal
Remove the red cover, fill the tank with
clean water and use maximum temperature
40 degree. Add appropriate low foaming
detergent according to dosage information.
Press the + or – buttons to increase /
decrease the solution flow rate.

Advertisement

loading

Summary of Contents for Viper AS4325B

  • Page 1 Use and maintenance Operating guidelines AS4325B Lift the deck by pressing the pedal Place the brush or the pad-holder under the Turn on the machine and verify there is enough battery power to complete the deck and Lower the deck or the brush/pad- work.
  • Page 2 Maintenance Operating guidelines AS4325B When scrubbing is complete, turn off the Daily: Empty the clean water tank using Daily: Empty the recovery tank using the on/off button to perform the following the solution tank drain knob under the recovery empty hose. Bend the soft part maintenance.