2. Manual and Timed Modes

The steamer has two operating modes: manual and timed. The TIMED/MANUAL rocker switch selects
the operating mode. Pressing the MANUAL end of the switch selects the manual-operating mode.
Pressing the TIMED end of the switch selects the timed (automatic) operating mode.
Press keypad with fingertips only. Do not use kitchen
utensils or anything sharp to operate the keypad.
1). TIMER Display
This four-digit display indicates the minutes and seconds remaining in the
count down. The display reads from zero (00:00) to 99 minutes and 99
seconds (99:99). It reads pause (PAUS) when the count down is halted
either by the START/STOP key or by the temperature compensating
1
circuit.
2). Number Pad Keys
These keys set the number of minutes and seconds in the timer count
down. Pressing the number keys 1 2 3 4 in this sequence, sets the timer
2
for 12 minutes and 34 seconds (12:34).
3). START/STOP Key
This key starts and stops the timer. In TIMED mode the steaming
functions are linked to the timer. In MANUAL mode, the steaming
functions are independent of the timer.
4
4). CLEAR Key
This key resets the timer to zero (00:00) after it has been stopped. The
timer must be zeroed by pressing this key before a new time can be set.
5). TIMED/MANUAL Switch
The TIMED/MANUAL switch selects the manual or timed operating mode.
·
Pressing the MANUAL end of the switch selects the manual mode.
·
5
Pressing the TIMED end of the switch selects the timed mode.
6). ON/OFF Switch (located on control panel for Gemini 10 only,
located below the lower compartment on the Gemini 6
The ON/OFF switch controls the start-up of the individual generators.
Each switch controls the power function of its individual generator and
cooking compartment only.
·
Turning switch to the ON position fills generator, turns indicator light
ON and energizes control panel.
6
·
Turning switch to the OFF position starts the blow down cycle, de-
energizes the heating system and the control panel.
7). Power on Indicator Light
When the Red indicator light is ON, power is ON to the control panel.
8). Descale Indicator Light Switch (not shown)
When the Amber light in the switch lights, it is time to descale the steam
generators. Pressing the switch turns off the light and resets the internal
timer which tracks steam generator operation. (See Chapter 6, Part A)