Note: Control panel for
Gemini 10 Shown
B. KEYPAD TIMER CONTROL PANEL
1. Cooking Operations – Keypad Timer Control Panel
For safe, efficient operation of the steamer, the operator must, at a minimum, comply with all cautions,
warnings and instructions in the detailed operating procedures and be familiar with the control panel
shown in Figure 3-2. The operator must be familiar with all the operating features explained in this
manual before attempting to operate the steamer.
1
1). PAUSE Indicator Light
This light is lit whenever the cooking compartment has not yet
reached cooking temperature. Note: when in the timed mode
2
the timer will not count down as long as this light is ON.
2). TIMER
This dial timer sets the operating time from 0 to 60 minutes.
Turn the dial clockwise until it points to the required number of
minutes. When it reaches 0, a buzzer sounds for 3 seconds.
3). TIMED/MANUAL Switch
The TIMED/MANUAL switch selects the manual or timed
operating mode.
· Pressing the MANUAL end of the switch selects the
manual mode.
· Pressing the TIMED end of the switch selects the timed
mode.
4). ON/OFF Switch (located on control panel for Gemini 10 only,
3
located below the lower compartment on the Gemini 6)
The ON/OFF switch controls the start-up of the individual
generators. Each switch controls the power function of its
individual generator and cooking compartment only.
·
Turning switch to the ON position fills the generator, turns
the indicator light ON and energizes the control panel.
4
·
Turning switch to the OFF position starts the blow down
cycle, de-energizes both the heating system and the
control panel.
5
5). Power on Indicator Light
When the Red indicator light is on, power is on to the control
panel.
6). Descale Indicator Light Switch (not shown)
When the Amber light in the switch lights, it is time to descale
the steam generators. Pressing the switch turns off the light
and resets the internal timer which tracks steam generator
operation. (See Chapter 6, Part A).