Startco SE-701 Manual

Startco SE-701 Manual

Ground-fault monitor
Hide thumbs Also See for SE-701:

Advertisement

Quick Links

Publication: SE-701-M
Document: S95-C701-00000
Printed in Canada.
SE-701 MANUAL
GROUND-FAULT MONITOR
December 14, 2006
Revision 5
Copyright © 2006 by Startco Engineering Ltd.
All rights reserved.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SE-701 and is the answer not in the manual?

Questions and answers

Summary of Contents for Startco SE-701

  • Page 1 SE-701 MANUAL GROUND-FAULT MONITOR December 14, 2006 Revision 5 Copyright © 2006 by Startco Engineering Ltd. All rights reserved. Publication: SE-701-M Document: S95-C701-00000 Printed in Canada.
  • Page 2: Table Of Contents

    2.3.3 Inhibit............3 Specifications are subject to change without notice. Analog Output ............3 Startco Engineering Ltd. is not liable for contingent or consequential damages, or for expenses sustained as a Installation ............3 result of incorrect application, incorrect adjustment, or a malfunction.
  • Page 3: General

    ELAY PERATING detection, the ground-fault trip level must be substantially The SE-701 has one output relay with isolated below the prospective ground-fault current. To avoid normally open and normally closed contacts. Switch 1 is sympathetic tripping, the trip level must be above the used to set the operating mode of the output relay.
  • Page 4: Se-701 Outline And Mounting Details

    Startco Engineering Ltd. Page 2 SE-701 Ground-Fault Monitor Rev. 4 FIGURE 1. SE-701 Outline and Mounting Details. Pub. SE-701-M, December 14, 2006.
  • Page 5: Test

    3. I NSTALLATION 2.2.4 T An SE-701 can be surface- or DIN-Rail-mounted. See The TEST switch is used to test the ground-fault Fig. 1. Panel mounting requires a PMA-55 Panel-Mount circuit, the indication, and the output relay. When the Adapter.
  • Page 6: Efct-1 Outline And Mounting Details

    RECESSED FOR FLUX 8-mm HEX NUT CONDITIONER 1.0 (0.04) DEEP (OPTIONAL) 110.0 56.0 (2.21) (0.22) (4.33) (0.22) FRONT SIDE NOTES: DIMENSIONS IN MILLIMETRES (INCHES). MOUNTING SCREWS: M4 OR 8-32. FIGURE 3. EFCT-1 Outline and Mounting Details. Pub. SE-701-M, December 14, 2006.
  • Page 7: Efct-2 Outline And Mounting Details

    25.0 (1.22) (0.98) FLUX CONDITIONER 5.0 (0.20) DIA (INCLUDED) BONDING SCREW 198.0 (0.33) (7.80) (0.33) FRONT SIDE NOTES: 1. DIMENSIONS IN MILLIMETRES (INCHES). MOUNTING SCREWS: M4 OR 8-32. FIGURE 4. EFCT-2 Outline and Mounting Details. Pub. SE-701-M, December 14, 2006.
  • Page 8: Efct-26 Outline And Mounting Details

    SIDE NOTES: MOUNTING FOOT INSTALLATION DIMENSIONS IN MILLIMETRES (INCHES). TOOL PRESS MOUNTING FEET IN PLACE USING INSTALLATION TOOL PROVIDED (DETAIL ‘A’) MOUNTING SCREWS: M4 OR 8-32. DETAIL ‘A’ FIGURE 5. EFCT-26 Outline and Mounting Details. Pub. SE-701-M, December 14, 2006.
  • Page 9: Pma-55 Panel-Mount Adapter

    Startco Engineering Ltd. Page 7 SE-701 Ground-Fault Monitor Rev. 5 FIGURE 6. PMA-55 Panel-Mount Adapter. Pub. SE-701-M, December 14, 2006.
  • Page 10: Technical Specifications

    1,400 VA inductive (PF = 0.4) Subject to maximums of 8 A and 250 V (ac or dc). Operating Mode ......Latching or Autoreset Terminals........Wire-clamping, 24 to 12 AWG (0.2 to 2.5 mm conductors Pub. SE-701-M, December 14, 2006.
  • Page 11: Ordering Information

    For maximum lead resistance of 1 Ω. repair, replace, or refund the original purchase price of an SE-701 that is determined by Startco to be defective if it is returned to the Startco factory, freight prepaid, within the warranty period. This warranty does not apply to...
  • Page 12: Ground-Fault Performance Test

    0.1 to 9.9 seconds. Set the test current to 120% of REMOTE SE-100T the SE-701 setting. Fig. 7 (b) shows a test circuit TEST using a Startco SE-100T Ground-Fault-Relay Tester. The SE-100T provides a test current of 0.65 or 2.75 A for testing 0.5- and 2.0-A trip levels.