When filling is complete, first turn off the cylinder's valve and then the filling hose connector's valve and
proceed to evaporation using the relief valve on the connector. Finally, safely disconnect the cylinder.
During the filling procedure, cylinder's temperature will rise. Let it cool down. Pressure will fall a little. If
you wish, reconnect the cylinder with the filling hose (following the same procedure) and fill until the
maximum filling pressure.
Never open the filling hose connector valve, unless the cylinder is connected to the filling
hose. Hose whipping due to pressurized air out system can cause serious injury!

Automatic stop system

 Standard equipment in all electrical versions.
 Optional equipment in petrol and diesel versions.
When the pressure reaches the pre-adjusted final level the compressor stops automatically {through the
pressure switch (1)}. The restart of the compressor must be done manually.
Max. operating pressure 350 bar.

Dual pressure filling module

 Optional equipment.
It controls the pressure through a pressure regulator (1) (0-345 bar outlet pressure) and gives the
possibility to the user to fill 200 and 300 bar cylinders simultaneously.
PARAMINA SA – Byway Evaggelistrias str. 19300 Aspropirgos, Greece, Tel: 0030 210 5575860-1
Fax: 0030 210 5575868, email:
12/2013 edition