DAB AD 2.2 AC Instruction For Installation And Maintenance page 70

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 64
1.2
Technical specifications
Table 1 shows the technical specifications of the products in the range referred to in this manual.
Voltage [VAC]
(Tol +10/-20%)
Inverter power
Phases
supply
Frequency [Hz]
Current [A]
Leakage current to earth [ma]
Voltage [VAC]
Phases
Frequency [Hz]
Maximum current[A rms]
Inverter output
Minimum pump current [A rms]
Max. power output [kVA] (400
Vrms)
Mechanical power P2
Unit weight [kg]
(excluding packaging)
Mechanical
Package weight [kg]
specifications
Maximum dimensions
[mm](WxHxD)
Work position
IP protection rating
Max. ambient temperature [°C]
Max. section of lead accepted by
input and output terminals [mm²]
Installation
Min. diameter of cable accepted
by input and output cable glands
[mm]
Max. diameter of cable accepted
by input and output cable glands
[mm]
Control and
Pressure regulation range [bar]
operating
hydraulic
Options
specifications
Type of pressure sensors
Sensors
Pressure sensor full scale [bar]
Type of flow sensor supported
Connectivity
Functions and
safety devices
Safety devices
ENGLISH
Technical specifications
AD 2.2 AC
220-240
1
50/60
25,0
<2,5
0 - V alim.
3
0-200
11,0
1
3,3
3 CV / 2,2 kW
Serial interface
Multi inverter connection
Dry running
Current sensitivity on output phases
Temperature overload on internal electronics
Abnormal power supply voltages
Direct shorting between output phases
Fault on pressure sensor
68
AD 1.5 AC
220-240
1
50/60
18,7
<2,5
0 - V alim.
3
0-200
9,0
1
2,3
2 CV / 1,5 kW
6,5
8,5
173x280x180
Any
20
50
4
6
12
1 – 95% full scale without press.
Flow sensor
Ratiometric (0-5V) / 4:20 mA
16 / 25 / 40
5 pulses [Vpp]
AD 1.0 AC
220-240
1
50/60
12,0
<2,5
0 - V alim.
3
0-200
6,5
1
1,4
1,3 CV / 1 kW

Advertisement

Table of Contents
loading

Table of Contents