Error Messages

Display
Cause
This three-part message (plus alarm) is
Shorted
displayed when the controller detects that
Probe
the oven temperature probe is shorted, or
Or
that the oven temperature is not rising, or is
rising too slowly.
Faulty
Heater
Turn off the alarm by pressing any button
on the control panel.
The controller has detected an overcurrent
Over
condition in the rotisserie drive motor. The
Current
alarm tone will sound continuously.
A power loss of more than 5 minutes will
Power
sound the alarm tone and display this
Loss
message. Press any button to cancel the
alarm.
This message is displayed (with alarm) if
Probe
the oven temperature probe fails open. If
Open
the open condition goes away before 20
seconds, the oven will return to its previous
state; however, the alarm must be turned off
by pressing the TEMP button
Checksum
This message is displayed upon power up if
Error
the controller detects a fault within one of
the Menu Item programs, or if new controller
software has been installed. Press any
button to acknowledge the message.
This is not an error message. It is displayed
Unused
when you are attempting to review a Menu
Item
Item button which has not been
programmed.
System
System
Init
Init
Version
New
CR xx.xx
Version
Rotisserie Oven
These are not error messages. They are
displayed upon power up of the oven,
when the software is initializing. The "New
Version" message is shown when new
software is detected for the first time.
Remedy
Open the door to check if there is any heat
at all. If there's no heat, either the probe is
open and the burners are kept off by the
controller, or the gas supply is turned off,
which you should check. If there is some
heat check that the gas valve is fully open.
If the gas is OK, then the problem will
require service.
The only way to turn off the alarm is to turn
power off to the oven and turn it back on.
Check for some obstruction of the drive
system. Call service if the error does not
go away.
A power loss of 5 minutes or less will not
sound the alarm or show this message.
When power returns, the cooking cycle will
resume where it left off. A longer loss will
cause the oven to reset and enter the
Preheat/Ready mode.
If the probe remains open, call for service.
Operator's Manual
20

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cr28-ddCr28-ffpCr28-fpCr32Cr32-ddCr32-ffp ... Show all

Table of Contents