LUBRICATION
Ingersoll–Rand No. 50
Always use an air line lubricator with these tools.
We recommend the following Filter–Lubricator–Regulator
Unit:
For International – No. FRL30–C6–A29
For Model 2934P2–EU
Before starting the tool and after each eight hours of
operation, unless the air line lubricator is used, unscrew the
Oil Chamber Plug and fill the chamber with Ingersoll–Rand
No. 50 Oil.
After each forty–eight hours of operation, or as experience
indicates, inject about 3 cc of Ingersoll–Rand No. 100 Grease
(approximately 14 strokes from the No. R000A2–228 Grease
Gun) into the Grease Fitting.
For Model 2940P2–EU
Before starting the tool and after each two or three hours
of operation, unless the air line lubricator is used, detach the
air hose an inject about 3 cc of Ingersoll–Rand No. 50 Oil into
the air inlet.
Model
Type of Grip
2934P2–EU
pistol
2940P2–EU
pistol
H
Tested in accordance with ANSI S5.1–1971 at free speed
Tested to ISO8662–1 loaded with frictionbrake to 9 RPM
ISO3744

PLACING TOOL IN SERVICE

Ingersoll–Rand No. 100
SPECIFICATIONS
Drive
Impacts per
in.
1" sq.
1"sq.
After each twenty hours of operation, or as experience
indicates, inject about 6 cc of Ingersoll–Rand No. 100 Grease
(approximately 14 strokes from the No. R000A2–228 Grease
Gun) into the Grease Fitting.
MAIN LINES 3 TIMES
AIR TOOL INLET SIZE
TO
AIR
SYSTEM
TO
AIR
TOOL
LUBRICATOR
REGULATOR
BRANCH LINE 2 TIMES
AIR TOOL INLET SIZE
DRAIN REGULARLY
H
Sound Level
min.
Pressure
825
92.4
810
97.2
3
FILTER
COMPRESSOR
(Dwg. TPD905–1)
dB (A)
Power
105.4
110.2
Vibrations
Level
2
m/s
9.1
9.3