MULTIQUIP GloBug GB4000 Operation And Parts Manual page 25

Light tower mount type balloon light
Hide thumbs Also See for GloBug GB4000:
Table of Contents

Advertisement

INFLA TING BALLOON ANDTURNING ON LAMPS
(MLT ONL Y)
1. OnMLTseries light towers, reconnect the4-pinpower
cable (Figure 13) tothe 120VACtwist-lock receptacle
on the front panel of the generator.
MLT LIGHT TOWER
4-PIN POWER
CABLE
Figure 13. MLT Ballast 4-pin
Power Cable
2. Slightly raise the light tower mast to allow clearance
for the balloon to inflate.
3. Start the light tower engine as referenced in the MLT
operation manual.
4. Once, the engine has started, place the main circuit
breaker switch (Figure 14) on the MLT front control
panel in the ON position.
MLT LIGHT TOWER
MAIN CIRCUIT
BREAKER
(ON)
4-PIN POWER
CABLE
Figure 14. Main, GFCI Circuit Breakers (ON/MLT)
GB4000 BALLOON LIGHT• OPERA TION AND PARTS MANUAL —REV . #1 (02/25/14) —PA GE
TO BALLAST
COMPARTMENT
TO BALLAST
COMPARTMENT
5. Next, turnonlampcircuit breakersTheballoonshould
begin to inflate and the lamps will light.
6. Secure any unused lamp cables.
7. Raisethelight towermast tothedesiredupright height.
DEFLA TING AND STORINGBALLOON
1. Turn lamps OFF and allow to cool for at least fi e
minutes.
2. Once the lamps have cooled, place the main breaker
switch in the OFF position.
NOTICE
ALWA YSmake sure lampsare turned off and allowed
to cool before deflating balloon to avoid any damage
to the balloon. NEVER transport GB4000 lamp fi ture
while attached to mast.
3. When the balloon is completely deflated, unzip the
protective cover and fold the balloon inside the cover.
4. Carefully zipupthecover andsnapthebuttons tofully
close the protective cover.
5. Remove all cables from T -Bar, and remove balloon
power cable fromjunction box.
6. Pull cotter pin from locking pin and remove lamp
assembly fromlight tower mast.
7. Store lamp assembly in a safe place where it will not
get damaged.