Summary of Contents for Maxx Cold X Series

  • Page 3: Serial Number Information

    SERIAL NUMBER INFORMATION The serial number of all self-contained refrigerators and freezers is located inside the unit on the left hand side near the top on the wall. Always have the serial number of your unit available when calling for parts or service. RECEIVING AND INSPECTING THE EQUIPMENT Use care during unloading so the equipment is not damaged while being moved...
  • Page 4: Specifications

    SPECIFICATIONS MXCR›23FD MXCR›49FD MXCR›72FD 14.1 MXCF›23FD MXCF›49FD 28.9 MXCF›72FD...
  • Page 5: Installation

    INSTALLATION Location: Units represented in this manual are intended for indoor use only. Be sure the loca- tion chosen has a floor strong enough to support the total weight of the cabinet and contents. A fully loaded unit can weigh as much as 1500 pounds. Reinforce the floor as necessary to provide for maximum loading.
  • Page 6: Operation

    INSTALLATION Electrical connection: Refer to the amperage data on page 3, the serial tag, your local code or the Na- tional Electrical Code to be sure the unit is connected to the proper power source. A protected circuit of the correct voltage and amperage must be run for connection of the line cord, or permanent connection to the unit.
  • Page 7: Key Combinations

    2. Anti-condensation heaters on door frames work in conjunction wi th the compres- sor. 3. The factory setting for temperature range is ,r to , 3" F On/Off Switch: An on/off switch is located on the front of the top shroud. When the unit is on, the switch will glow green.
  • Page 8: Main Functions

    2. MAIN FUNCTIONS confirm Condenser probe failane Condenser alarm HOW TO SEE THE ALARM AND RESET THE RECORDED ALARM 1. Push the UP or Down key, the alarm signals are displayed. 2. When the signal is displayed, hold the SET key untill the "rst" message is displayed, and push the SET again, the "rst"...
  • Page 9 denser coil.If heavy grease is present there are de-greasing agents available for re- frigeration use and specifically for the condenser coils. The condenser coil may re- quire a spray with the de-greasing agent and then blown through with compressed air.Failure to maintain a clean condenser coil can initially cause high temperatures and excessive run times, continuous operation with dirty or clogged condenser coils can result in compressor failures.
  • Page 10 MAINTENANCE always good to rub with the grain of the steel. There are also stainless steel cleaners available which can restore and preserve the finish of the protective layer. Early signs of stainless steel breakdown can consist of small pits and cracks. If this has begun, clean thoroughly and start to apply stainless steel cleaners in attempt to re- store the passivity of the steel.
  • Page 11 MAINTENANCE ing water to back up and overflow the drain pans. Open the top shroud Loosen the screws on the bottom of top shroud, then swing top shroud up 180° until it rest on top of the cabinet. Door Replacement and Adjustment 1.
  • Page 12 WIRING DIAGRAM MXCR›23FD MXCR›49FD 56R,82R MXCR›72FD...
  • Page 13 WIRING DIAGRAM MXCF›23FD MXCF›49FD 56F,82F MXCF›72FD...
  • Page 14 WIRING DIAGRAM...
  • Page 15 WIRING DIAGRAM...
  • Page 16 WIRING DIAGRAM...
  • Page 17 WIRING DIAGRAM...
  • Page 18 WIRING DIAGRAM...
  • Page 19 WIRING DIAGRAM...