Table 27. Supported rear video resolution options
Resolution
1024 x 768
1280 x 800
1280 x 1024
1360 x 768
1440 x 900
1600 x 900
1600 x 1200
1680 x 1050
1920 x 1080
1920 x 1200

Environmental specifications

Operational climatic range category A2
Table 28. Operational climatic range category A2
Allowable continuous operations
Temperature ranges for altitude <900 meters (<2,953 feet)
Humidity percent ranges (Non-condensing at all times)
Operational altitude de-rating
Operational climatic range category A3
Table 29. Operational climatic range category A3
Allowable continuous operations
Temperature ranges for altitude <900 meters (<2,953 ft)
Humidity percent ranges (Noncondensing at all times)
Operational altitude de-rating
Refresh rate (Hz)
60
60
60
60
60
60
60
60
60
60
10 to 35°C (50 to 95°F) with no direct sunlight on the
platform
8% RH with -12°C minimum dew point to 80% RH with 21°C
(69.8°F) maximum dew point
Maximum temperature is reduced by 1°C/300 meters
(1.8°F/984 feet) above 900 meters (2,953 feet)
5°C- 40°C (41°F-104°F) with no direct sunlight on the
platform
8% RH with -12°C minimum dew point to 85% RH with 24°C
(75.2°F) maximum dew point
Maximum temperature is reduced by 1°C/175 meters
(1.8°F/574 feet) above 900 meters (2,953 feet)
Color depth (bits)
8, 16, 32
8, 16, 32
8, 16, 32
8, 16, 32
8, 16, 32
8, 16, 32
8, 16, 32
8, 16, 32
8, 16, 32
8, 16, 32