Operation; Operation Range; Operation Mode And Temperature Setpoint; To Start/Stop Operation Mode And To Set The Temperature - Daikin FTXTA30B2V1BW Operation Manual

Hide thumbs Also See for FTXTA30B2V1BW:
Table of Contents

Advertisement

5

Operation

5.1

Operation range

Use the system in the following temperature and humidity ranges for
safe and effective operation.
Operation mode
(a)(b)
Cooling
▪ Outdoor temperature: –10~46°C DB
▪ Indoor temperature: 18~32°C DB
▪ Indoor humidity: ≤80%
(a)
Heating
▪ Outdoor temperature: –25~24°C DB
▪ Indoor temperature: 10~30°C DB
(a)
Drying
▪ Outdoor temperature: –10~46°C DB
▪ Indoor temperature: 18~32°C DB
▪ Indoor humidity: ≤80%
(a)
A safety device might stop the operation of the system if the unit
runs outside its operation range.
(b)
Condensation and water dripping might occur if the unit runs
outside its operation range.
5.2
Operation mode and temperature
setpoint
When. Adjust the system operation mode and set the temperature
when you want to:
▪ Heat up or cool down a room
▪ Blow air in a room without heating or cooling
▪ Decrease the humidity in a room
What. The system operates differently, depending on the user
selection.
Setting
The system cools down or heats up a
Automatic
room to the temperature setpoint. It
automatically switches between cooling
and heating if necessary.
The system decreases the humidity in a
Drying
room.
The system heats up a room to the
Heating
temperature setpoint.
The system cools down a room to the
Cooling
temperature setpoint.
The system only controls the airflow
Fan
(airflow rate and airflow direction).
The system does NOT control the
temperature.
Additional info:
▪ Outside temperature. The system's cooling or heating effect
decreases when the outside temperature is too high or too low.
▪ Defrost operation. During heating operation, frost might occur on
the outdoor unit and decrease the heating capacity. In that case,
the system automatically switches to defrosting operation to
remove the frost. During defrosting operation, hot air is NOT
blown from the indoor unit.
FTXTA30B2V1B(W)(B)
Daikin room air conditioner
3P485919-13U – 2021.03
Operation range
Description
5.2.1
To start/stop operation mode and to set
the temperature
: Unit is operating.
: Operation mode = Automatic
: Operation mode = Drying
: Operation mode = Cooling
: Operation mode = Heating
: Operation mode = Fan only
: Shows the set temperature.
1 Press
one or more times to select the operation mode.
Result: The mode will be set as follows:
2 Press
to start operation.
Result:
and the selected mode are displayed on the LCD.
3 Press
or
one or more times to lower or raise the
temperature.
Cooling
Heating
operation
operation
18~32°C
10~30°C
Note: When using drying or fan only mode, you cannot adjust the
temperature.
4 Press
to stop operation.
Result:
disappears from the LCD. The operation lamp goes
off.
5.3

Airflow rate

INFORMATION
▪ When using drying operation mode, you CANNOT
adjust the airflow rate setting.
▪ The airflow rate in heating mode will lower to avoid
generating cold airflow. When temperature of the
airflow rise, operation will continue at the set airflow
rate.
1 Press
to choose:
5 airflow rate levels, from "
Automatic airflow rate operation
Indoor unit quiet operation. When the airflow rate is
set to "
", the noise from the unit will be reduced.
INFORMATION
If the unit reach the temperature setpoint:
▪ in cooling or automatic mode. Fan will stop operating.
▪ in heating mode. Fan will operate in low airflow rate.
5.3.1

To adjust the airflow rate

1 Press
to change the airflow setting as follows:
5 Operation
Automatic
Drying or Fan
operation
only operation
18~30°C
" to "
"
Operation manual
7