Recommended Tube Diameters; Check-Flo-Rater Piston; Charging Subcooling (Txv-Type Expansion Device*) - Bryant DELUXE 11 SEER R-410A User Manual

Deluxe 11 seer air conditioner with puron
Table of Contents

Advertisement

UNIT
SIZE
018
024
030, 036
042, 048
060
* For tube sets greater than 50 ft, consult Application Guideline and Service Manual—Air Conditioners and Heat Pumps Using Puron® Refrigerant.
CERTIFICATION APPLIES ONLY
WHEN THE COMPLETE SYSTEM
IS LISTED WITH ARI.

RECOMMENDED TUBE DIAMETERS

Liquid Tube Diameter (In.)
0 to 50 Ft
Tube Length
Long-Line Applications*
3/8
CHECK-FLO-RATER® PISTON
UNIT SIZE–SERIES
018-A
024-A
030-A
036-A
042-A
048-A
060-A
* Piston listed is for any approved non-capillary tube coil combination. Piston is shipped
with outdoor unit and must be installed in an approved indoor coil.

CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE*)

UNIT SIZE–SERIES
018-A
024-A
030-A
036-A
042-A
048-A
060-A
* Must be a Puron® approved hard shutoff TXV.
®
As an ENERGY STAR
partner, Bryant Heating &
Cooling Systems has
determined that this prod-
uct meets the ENERGY
®
STAR
guidelines for
energy efficiency.
0 to 50 Ft
Tube Length
5/8
5/8
3/8
3/4
7/8
1-1/8
PISTON*
IDENTIFICATION NO.
49
59
63
67
73
78
90
REQUIRED SUBCOOLING (°F)
15
15
16
18
18
16
14
REGISTERED QUALITY SYSTEM
—3—
Vapor Tube Diameter (In.)
Long-Line Applications*
(Maximum Diameter)
3/4
3/4
7/8
1-1/8
1-1/8