Regardless of your level of experience with similar devices in the past, you should carefully read and understand the contents of this manual before installing, operating, or servicing this product. In case of any questions, please contact Spencer Italia S.r.l. for the necessary clarifications.
4.4 WARRANTY AND SERVICE Spencer Italia S.r.l. guarantees that products are free from defects for a period of one year from the date of purchase. For information regarding correct interpretation of the instructions for use, maintenance, installation or return, please contact Spencer Customer Service tel.
• Anyone who modifies or causes products manufactured by Spencer Italia S.r.l. to be modified or re-processed in such a way that they no longer serve the intended purpose or no longer provide the intended performance shall comply with the conditions valid for the first placing on the market.
General warnings for medical devices The user must carefully read the following in addition to the general warnings. • The application of the device should not last longer than the time required for first aid operations and subsequent transport to the nearest rescue point.
• If the twist system has been activated, make sure that the wheels are locked again before loading the stretcher into the ambulance as this can be risky and difficult with the front wheels unlocked. • Movement with four swivel wheels can be very difficult on sloping or uneven ground. Carefully assess the conditions of use before unlocking the front wheel pivot.
TECHNICAL DATA AND COMPONENTS Note: Spencer Italia S.r.l. reserves the right to make changes to specifications without notice. See Callout Image P2 – P3 – P4 – P5 Description Material Description Material Frame – Stretcher supporting Steel Crossbar for front fixing – Element...
To facilitate insertion of the stretcher into the ambulance, eliminate sharp edges on the edge of the ambulance loading floor. The stretcher should be secured using Spencer hooks in such a way as to prevent any movement during transport in the ambulance, even in difficult driving conditions.
See image P7 - Stretchers intended for use with the Sensor Lock fixing system, identified as "SL", are equipped with a communication system with the fixing system installed on the fifth wheel of the stretcher. Before putting into service, check that the unlocking system is working properly.
• Lock the stretcher on the medical vehicle using the Spencer fixing system installed on the vehicle. Warning: DURING NORMAL STRETCHER MOVEMENTS, NEVER ENGAGE THE LEG LOCKING LEVERS, AS DOING SO COULD CAUSE THE STRETCHER TO FALL TO THE GROUND. THESE LEVERS MUST ONLY BE ENGAGED TO LOAD THE STRETCHER ON THE AMBULANCE OR TO REACH THE INTERMEDIATE HEIGHT AS DESCRIBED ABOVE.
11.8 Changing the stretcher length (ACTIV only) – Image P20 – P21 The Spencer Carrera Activ has been designed to facilitate manoeuvres inside particularly confined spaces (e.g. lifts). It is possible to reduce the maximum length as follows: • Raise the backrest of the stretcher to a vertical position.
Do not use the boards or other areas that are not designed for this purpose. 11.10 Telescopic handle operation - Image P26 Carrera Tec TH is equipped with telescopic handles that allow it to be lifted over small obstacles, temporarily avoiding the transmission of stress from the ground to the patient.
Please note that cleaning must be carried out as described in this manual and that functionality must be verified before and after each use. Spencer Italia S.r.l. declines any responsibility for improper functioning or damages caused to the patient or user by the use of devices not subject to routine maintenance and will void the warranty and compliance to Medical Device Directive 2017/745/EU.
Spencer Italia S.r.l. will accept no responsibility for incorrect operation or damage caused by the use of devices that have not been overhauled by the Manufacturer or authorized centre, or that have exceeded the maximum allowable life span.
Page 21
Check the fixing system power supply. If the The Sensor Lock fixing system is problem persists, immediately remove the device not powered, is locked or is faulty. from service and contact the service centre. The stretcher is used with a fastener that does not provide If necessary, request a different fixing system.