Hot Water Operation - V-TUF RAPID VSC DEM Instructions Use And Maintenance

Table of Contents

Advertisement

RAPID-VSC-DEM
13.1.2 H
OT WATER OPERATION
Repeat step 1 and step 2 of cold water operation (previous paragraph).
Check that the thermostat(tr) is set to 0°C.
Switch on the burner with the burner switch (br), the corresponding indicator light (b) will light up,
Wait 30 seconds for the diesel pump to fill up,
Using the thermostat(tr), turn the knob to the desired temperature (once the required temperature has
been reached, the burner will automatically stop and then switch on again whenever the temperature
drops).
Act on the gun lever(3) to obtain water delivery from the wand,
Ensure that this forms a uniform fan (4), exiting the wand and then start work.
STEAM USE:
turn the RED steam tap, the flow rate will decrease, consequently the temperature will exceed 100°C and steam will start to escape.
At the end of the work:
Instructions - user maintenance manual
INSTRUCTIONS
Check that the diesel tank is full(1); if not,
fill it up using diesel fuel only
B
Br
- ©02/20 Rev:1.0/TRANSLATION OF THE ORIGINAL
Tr
Page 33

Advertisement

Table of Contents
loading

Table of Contents