Note
If you do not perform any operation for
about two minutes after pulling out the
crown, crown operations will
automatically become disabled. If that
happens, push the crown back in and
then pull it out again.
The watch will automatically return to
the Timekeeping Mode if you do not
perform any operation in the Altimeter
Mode for about one hour while [0'05] is
selected as the measurement interval
or about 12 hours while [2'00] is
selected.

Recording Altitude Readings

Use the procedure below to record altitude
measurements manually. Auto
measurements are also recorded
automatically.
Use the Altitude Record Recall Mode to
view or delete records.
Viewing Altitude Records
l
Recording Altitude Data Manually
1.
Enter the Altimeter Mode.
Navigating Between Modes
l
2.
Hold down (A) for at least two seconds
until [REC] stops flashing on the display.
This records the current altitude, date,
and time.
There is enough memory to hold up to
30 altitude records.
Recording altitude data when there are
already 30 records in memory
automatically deletes the oldest record
to make room for the new one.
Watch Operation Guide 5678
Auto Altitude Data Recording
The altitude data described below is recorded
automatically while the watch is in the Altitude
Mode. One record each is maintained in
memory for each of these items.
Start point
A
High Altitude (MAX):
Low Altitude (MIN):
Cumulative Ascent (ASC):
Cumulative Descent (DSC):
* Cumulative ascent and cumulative descent
values are updated whenever there is a
difference of at least ±15 m (±49 feet) from
one reading to the next.
Note
Auto recording ends when you exit the
Altimeter Mode. Re-entering the
Altimeter Mode restarts recording of
cumulative values from where it was
stopped when you last exited the
Altimeter Mode.
E
C
D
B
F
End point
E
F
+
*
A
C
+
*
B
D
Specifying the Altitude
Measurement Unit
You can select either meters (m) or feet (ft) as
the Altimeter Mode display unit.
Important!
When Tokyo (TYO) is set as the Home
City, the altitude unit is fixed as meters
(m) and cannot be changed.
1.
Enter the Altimeter Mode.
Navigating Between Modes
l
2.
Pull out the crown.
This displays the current altitude and
enters the Altitude Offset Mode.
3.
Press (B) three times.
This causes [UNIT] to appear, with [m] or
[ft] flashing.
4.
Rotate the crown to select an altitude unit.
[m]: Meters
[ft]: Feet
Meters
5.
Push the crown back in to complete the
setting operation.
Note
If you do not perform any operation for
about two minutes after pulling out the
crown, crown operations will
automatically become disabled. If that
happens, push the crown back in and
then pull it out again.
Crown
Feet