Download Print this page

Ryobi Homelite RY48ZTR75/100 Manual page 37

Electrical components troubleshooting and testing

Advertisement

Testing 48V-to-12V (DC-DC) Converter
48V-to-12V converter module
< Table of Contents
Testing Converter Fuse:
1. DISCONNECT MAIN POWER.
2. Check continuity of fuse (see next page)
3. If fuse is bad, replace only with same type
and Amperage
Testing Converter:
1. Turn mower on. Set DMM to "DC Volts"
2. Measure ~48V between Red and black wire
as indicated.
3. Check for 12V output at blue and yellow wire.
To test Converter Module Independently:
1. Apply 48V "+" to Red
2. Apply "-" to black wire.
3. Check for 12V output at blue and green wire.
Red and Black are 48V input
Blue and green are 12V output
Yellow is an enable wire (48V) to turn on the output
(12V, 2A automotive fuse)
AND
Yellow wire.