48V DC
Note this switch operates at
To measure Switch with wires disconnected:
1. Set DMM to measure continuity
OFF position:
No continuity between green and red wire.
ON position:
Continuity between green and red wire.
AUX position:
Not used at time of this writing.
< Table of Contents
Testing Key Switch
1. Set DMM to DC Volts
2. With Power switch OFF, measure battery voltage where indicated
3. With Power ON, measure approx. 0V where indicated