Yamaha YFZ450S 2003 Service Manual page 130

Table of Contents

Advertisement

CHECKING AND CHARGING THE BATTERY
NOTE:
_
• The charge state of an MF battery can be
checked by measuring its open-circuit volt-
age (i.e., the voltage when the positive termi-
nal is disconnected).
• No charging is necessary when the open-cir-
cuit voltage equals or exceeds 12.8 V.
b. Check the charge of the battery, as shown
in the charts and the following example.
Example
c. Open-circuit voltage = 12.0 V
d. Charging time = 6.5 hours
e. Charge of the battery = 20 ~ 30%
L
LLL
L LLL
L
L LLL
6. Charge:
• battery
(refer to the appropriate charging method
illustration)
WARNING
_
Do not quick charge a battery.
CAUTION:
_
• Never remove the MF battery sealing
caps.
• Do not use a high-rate battery charger
since it forces a high-amperage current
into the battery quickly and can cause
battery overheating and battery plate
damage.
• If it is impossible to regulate the charging
current on the battery charger, be careful
not to overcharge the battery.
• When charging a battery, be sure to
remove it from the machine. (If charging
has to be done with the battery mounted
on the machine, disconnect the negative
battery lead from the battery terminal.)
• To reduce the chance of sparks, do not
plug in the battery charger until the bat-
tery charger leads are connected to the
battery.
3 - 58
CHK
ADJ
L
L LLL
L
L LLL
L
L LLL
L
LLL

Advertisement

Table of Contents