Cleaning / Diagnostic - Vauconsant EXIGENCE User Manual

Advertisement

Always take care to switch off the appliance with energy doser, thermostat and switch before
cleaning. This unit is not impermeable to water. Do not use a high pressure water jet to clean it
inside or out.
Every day:
Metal surfaces:
Stainless steel should be cleaned with soapy warm water or a special product for high quality
metal surfaces. Never use abrasive sponges or scourers to avoid scratching the surface.
Glass (breath shield):
All glass displays must be cleaned using a high quality glass cleaning product and clean cloth.
Never use abrasive sponges or scourers to avoid scratching the surface.
Symptoms
Possible causes
No electricity supply
Light off, no heat
Defective contactor
Light on, no heat
Cable disconnected or cut
Defective heating element
Water inlet closed
The well is not
Water level poorly adjusted
filled
Defective solenoid valve
The water does
Water level poorly adjusted
not stop running
No electricity supply
Light off, no
heating or
ventilation
Defective heating element
Cable disconnected or cut
Light on, no heat
Defective safety thermostat
Ventilator blocked or defective
Light on, no
ventilation
Cable disconnected or cut
Halogen bulb burnt
A halogen lamp
does not come
Supply of this defective
on
No electricity supply
None of the
halogen lights
come on
Defective switch
NB
Bulbs should be replaced with bulbs of equivalent power. (see the Spare Parts section)
Fuses should be replaced by gG fuses of the same calibre.
Vauconsant SA, all rights reserved A623xx -rev0-ENG, 14/10/2010
Cleaning
Diagnostic
Check the general circuit breaker
Burnt fuse
Check the fuse in the electric cabling
Faulty supply
Check the supply cable
Replace the contactor
Check and test the electric input on the heating elements
Replace the heating element
Check the water inlet
Re-adjust the water level see "Installation" section
Check that the solenoid valve works properly.
Re-adjust the water level see "Installation" section
Check the general circuit breaker
Burnt fuse
Check the fuse in the electric cabling
Faulty supply
Check the supply cable
Replace the heating element if necessary
Check and test the electric input on the heating elements
Check and test the electric inlet on the safety thermostat.
Clean or replace the ventilator
Check and test the electric input on the ventilator
Replace the bulb with one of equivalent power
Check supply of halogen
halogen
Check the general circuit breaker
Burnt fuse
Check the fuse in the electric cabling
Faulty supply
Check the supply cable to the heating display
Check the switch, replace it if necessary
USER MANUAL
Remedies
- 8 -