Page 1
USER MANUAL – – A63513 (3GN) : 1385 x 820 x 900 mm A63515 (4GN) : 1580 x 820 x 900 mm A63517 (4GN) : 1580 x 820 x 900 mm A63519 (5GN) : 1930 x 820 x 900 mm...
These units comply with applicable EC norms and should be installed and used following the instructions in this manual to ensure good performance and to be covered by the warranty. Vauconsant SA, all rights reserved A635xx -rev0-ENG, 22/10/2010 - 3 -...
"salad bar" option, centre the glass. 4. Tighten the upper brackets. Upper glass brackets • Overhang adjustment The unit’s overhangs should be positioned as shown below. The unit should be level. Vauconsant SA, all rights reserved A635xx -rev0-ENG, 22/10/2010 - 4 -...
Page 5
Assembly / dismantling of facing • Step 1 Mounting with spanner (rack supply Step 2 • Option with condensation generator not supplied The connection should be done by a professional refrigerating technician. Vauconsant SA, all rights reserved A635xx -rev0-ENG, 22/10/2010 - 5 -...
See section "User instructions for the XW40L thermostat" Automatic defrosting This function is built into the thermostat, it is set in the factory. See section "User instructions for the XW40L thermostat" Vauconsant SA, all rights reserved A635xx -rev0-ENG, 22/10/2010 - 6 -...
Faulty connections Check the generator's connections Fuses should be replaced by the same type and same caliber fuses. If you have not solved your problem, contact a professional refrigerating technician. Vauconsant SA, all rights reserved A635xx -rev0-ENG, 22/10/2010 - 7 -...
Every year, check that the condenser's ventilator works properly. The installer should check electric connections when commissioning the unit then once a year. Any maintenance operations should be done by a professional. Vauconsant SA, all rights reserved A635xx -rev0-ENG, 22/10/2010 - 8 -...
Page 9
3 seconds. The "POF" message is displayed and the keyboard is locked. It is then only possible to see the set point, minimum and maximum temperatures and activate or de-activate the lights and regulator. Vauconsant SA, all rights reserved A635xx -rev0-ENG, 22/10/2010 - 9 -...
Page 10
To enter "Pr1" (settings accessible to the user): Enter the programming mode by pressing simultaneously on the SET and DOWN keys for a few seconds ( flash). The regulator displays the 1st setting in "Pr1". Vauconsant SA, all rights reserved A635xx -rev0-ENG, 22/10/2010 - 10 -...
Page 11
Interval between defrosting cycles (Maximum) defrosting time High temperature alarm Minimum temperature alarm Atmospheric probe calibration Serial address (not used) Access to the list of protected settings (read only) Vauconsant SA, all rights reserved A635xx -rev0-ENG, 22/10/2010 - 11 -...
Page 12
USER MANUAL Generator option supplied Electric diagram Refrigeration diagram Vauconsant SA, all rights reserved A635xx -rev0-ENG, 22/10/2010 - 12 -...
Page 13
Ballast Compressor Coil Capillary Starter Condenser Temperature probe Reducing valve XW40L thermostat Dehydrator Fluorescent tube Defrosting contactor Va Schraeder 1/4 connection Fuse holder Condenser ventilator Evaporation well heating element Vauconsant SA, all rights reserved A635xx -rev0-ENG, 22/10/2010 - 13 -...
Page 14
Water resistant sheath for 1,500mm tube Technical support sav@vauconsant.com Spare Parts Department: +33 (0)3 83 45 82 78 Hotline: +33 (0)3 83 45 44 48 Fax: +33 (0)3 83 45 82 75 Vauconsant SA, all rights reserved A635xx -rev0-ENG, 22/10/2010 - 14 -...
In any case, Vauconsant's civil liability, for all causes, with the exception of corporal damage and fraud or serious misdemeanour, may not exceed the sum of the contract.