Page 1
A62319 (5GN) : 1930 x 820 x 900 (+430) mm A62322 (6GN) : 2280 x 820 x 900 (+430) mm Exigence School range E62313TI (3GN) : 1380 x 820 x 900 (+430) mm E62315TI (4GN) : 1580 x 820 x 900 (+430) mm...
These units comply with applicable EC norms and should be installed and used following the instructions in this manual to ensure good performance and to be covered by the warranty. Vauconsant SA, all rights reserved A623xx -rev0-ENG, 14/10/2010 - 3 -...
Normal pressure of use: 4 bars. For higher pressure, use a pressure control valve to avoid dysfunction or deterioration of the solenoid valve Connect the drainage hose to the floor. Vauconsant SA, all rights reserved A623xx -rev0-ENG, 14/10/2010 - 4 -...
Page 5
The unit’s overhangs should be positioned as shown below. The unit should be level. Assembly / dismantling of facing • Step 1 Mounting with spanner (rack supply Step 2 Vauconsant SA, all rights reserved A623xx -rev0-ENG, 14/10/2010 - 5 -...
Page 6
A mechanical thermostat with orange on-off light for the bain-marie well. A mechanical thermostat with orange on-off light for the ventilated heat cupboard. A switch with orange light for the heating display option. Vauconsant SA, all rights reserved A623xx -rev0-ENG, 14/10/2010 - 6 -...
30°C to 85°C. The heat cupboard is recommended to store plates. It works with doors closed. Heating display (option) Press the switch: Position 0: Off Position 1: On. Vauconsant SA, all rights reserved A623xx -rev0-ENG, 14/10/2010 - 7 -...
Check the switch, replace it if necessary • Bulbs should be replaced with bulbs of equivalent power. (see the Spare Parts section) • Fuses should be replaced by gG fuses of the same calibre. Vauconsant SA, all rights reserved A623xx -rev0-ENG, 14/10/2010 - 8 -...
The ventilator is fixed by 3 screws, the heating elements are fixed by 2 nuts, use a Ø19 flat spanner to remove them. Heating Ventilation deflector elements fixing sheet Heating elements Heating elements sheet support Ventilator support Ventilator Casing Vauconsant SA, all rights reserved A623xx -rev0-ENG, 14/10/2010 - 9 -...
Page 10
Electric cabling is fixed behind the built-in control panel. To access this, remove the 4 screws holding the panel. The installer should check electric connections when commissioning the unit then once a year. Any maintenance operation should be done by an electrician. Vauconsant SA, all rights reserved A623xx -rev0-ENG, 14/10/2010 - 10 -...
USER MANUAL Electric diagrams Heating element coupling diagram SINGLE-PHASE THREE-PHASE Vauconsant SA, all rights reserved A623xx -rev0-ENG, 14/10/2010 - 11 -...
Page 12
Number of tangential ventilators in the 35 W heat cupboard cupboard Heat cupboard's total power (W) 1535 Unit's total power (W) 2 285 3 735 gG (A) fuse calibre Vauconsant SA, all rights reserved A623xx -rev0-ENG, 14/10/2010 - 12 -...
Page 13
Number of tangential ventilators in the 35 W heat cupboard cupboard Heat cupboard's total power (W) 1535 1535 3 070 3 070 Unit's total power (W) 3 785 4 535 6 820 7 570 gG (A) fuse calibre Vauconsant SA, all rights reserved A623xx -rev0-ENG, 14/10/2010 - 13 -...
Page 14
Heat cupboard's total power (W) Heating Number of halogen lamps, 200W display Total power of the heating display (W) Unit's total power (W) 2 685 gG (A) fuse calibre Vauconsant SA, all rights reserved A623xx -rev0-ENG, 14/10/2010 - 14 -...
Page 15
Heating display Total power of the heating display (W) 1 000 1 200 Unit's total power (W) 4 385 5 335 7 820 8 770 gG (A) fuse calibre Vauconsant SA, all rights reserved A623xx -rev0-ENG, 14/10/2010 - 15 -...
In any case, Vauconsant's civil liability, for all causes, with the exception of corporal damage and fraud or serious misdemeanour, may not exceed the sum of the contract.
Need help?
Do you have a question about the EXIGENCE and is the answer not in the manual?