Always take care to switch off the appliance with energy doser before cleaning. This unit is not
impermeable to water. Do not use a high pressure water jet to clean it inside or out.
Every day:
Metal surfaces:
Stainless steel should be cleaned with soapy warm water or a special product for high quality
metal surfaces. Never use abrasive sponges or etching agent to avoid scratching the surface.
Glass (breath shield):
All glass displays must be cleaned using a high quality glass cleaning product and clean cloth.
Never use abrasive sponges or etching agent to avoid scratching the surface.
Symptoms
Orange light off
No heat
Defective toughened glass
Orange light on
No heat
Cable disconnected or cut
A halogen lamp
Supply of this defective
does not come on
None of the
halogen lights
come on
NB
Bulbs should be replaced with bulbs of equivalent power. (see the Spare Parts section)
Fuses should be replaced by gG fuses of the same caliber.
Vauconsant SA, all rights reserved A622xx & E633xx -rev0-ENG, 2/12/2010
Cleaning
Diagnostic
Possible causes
No electricity supply
Burnt fuse
Faulty supply
plate
Halogen bulb burnt
halogen
No electricity supply
Burnt fuse
Faulty supply
Defective switch
USER MANUAL
Remedies
Check the general circuit breaker
Check the fuse in the electric cabling
Check the supply cable
Replace the toughened glass plate
Check and test electricity input to the toughened glass
Replace the bulb with one of equivalent power
Check supply of halogen
Check the general circuit breaker
Check the fuse in the electric cabling
Check the supply cable to the heating display
Check the switch, replace it if necessary