6.2.10 bACK FLOw PREVENTION VALVE
Remove the 8 Torx screws holding the cover plate onto the air arm and gently pull cover away from the seal.
The Back Flow Prevention Valve (BFPV) is located inside the cover itself and can be slid out for inspection.
Inspect BFPV for damage and operation. Replace if necessary
Inspect air arm seal for damage. Replace if necessary
Assembly is the reverse
6.2.11 OVERHEAT THERMOSTAT
Locate the overheat thermostat behind the GUI bridge (see illustration below)
Remove the thermostat from the clip by pushing the assembly upwards
Disconnect the two wires
Assembly is the reverse
6.2.12 AIR PRESSuRE SwITCH
Remove the two electrical connections from the air pressure switch
Remove the air tube
Unclip the air pressure switch from the connection ring.
Fitting is the reverse
Maintenance
Push thermostat
upwards
64
Tube on rear connector
MAXXflo EVO