11. MENU' 06 MODE STAND-BY

Important premise: regardless of which value is set in the STAND BY MENU (therefore both ON and OFF), the appliance always goes into
MODULA (i.e. it goes to minimum power 1) when it reaches the DESIRED AMBIENT TEMPERATURE -0.5 ° C and returns to the previous
operating power when the temperature drops by -2 ° C from the DESIRED AMBIENT TEMPERATURE.
Example: If you set the appliance to power 5 and the desired room temperature = 20 ° C, the appliance at 19.5 ° C (fixed delta of 0.5 ° C) will
change to power 1 modulation and will continue to remain at the minimum power until the temperature drops to 18 ° C (fixed delta of 2 ° C), at this
point it will restart at power 5.
The STAND BY MENU intervenes after the MODULA and operates differently depending on the set value:
- If set to ON: when the appliance reaches the desired room temperature (-0.5 ° C), it switches to MODULA at power 1, if, remaining at power 1, the
temperature nevertheless increases by more than 2 ° C desired room, after 5 minutes the appliance switches off automatically and will automatically
switch back on when the temperature drops by 2 ° C from the set temperature (and the safety conditions allow it).
- If set to OFF (default and recommended setting): the appliance will never turn off automatically but will simply switch to MODULA at power 1 and
then restart at the previous power set once the room temperature has fallen.
°
To modify
Special features for IDRO models
In the IDRO models the appliance goes into MODULA even when the water temperature is reached. Example if you set the DESIRED WATER
TEMPERATURE at 70 ° C and power 5, a few degrees before reaching the DESIRED WATER TEMPERATURE (example at 65 ° C) the appliance
starts automatically lowering the power to 4, then to 3, 2 and so on via so that it reaches the DESIRED WATER TEMPERATURE value without
exceeding it, then returning to the previous power set when the water temperature drops.
Furthermore, if the STAND BY MENU is set to ON and the water temperature, despite the appliance being in MODULA, continues to rise and this
condition persists for more than 5 minutes, the machine will switch off automatically and will automatically switch back on when the WATER
temperature will drop 1 ° C from the set H2O temperature (and the safety conditions allow it). In the previous example when the water temperature
of the probe reaches 74 ° C and this temperature is maintained for 5 'then the machine will go off for stand-by and will turn on again at 69 ° water
temperature (always if the STAND BY MENU is set in ON).
Special features EXTERNAL CHRONOTHERMOSTAT
If the appliance is connected to an external chronothermostat (see chapter 26 for all settings), in this case the appliance will not go into modulation
upon reaching the DESIRED AMBIENT temperature but will switch off automatically when the temperature is exceeded by 2 ° C desired room for a
minimum time of 5 minutes and it will automatically turn on again when the temperature drops by 2 ° C from the set temperature (and the safety
conditions allow it).

12. MENU' M07 MODE BUZZER

Allows you to enable (ON) or disable (OFF) the buzzer alarms.
°
To modify
L'ARTISTICO SRL |