Earth fault in the feedback loop:
Detected, depending on the base unit that is used.
}
Earth fault in the input circuit:
The output relays de­energise and the safety contacts open.
Block diagram/terminal configuration
*Insulation between the non­marked area and the relay contacts: Basic insulation (over­
voltage category III), Protective separation (overvoltage category II)
Function description
The contact expansion module is an add­on device with delay­on de­energisation, and it is
used to expand a safety circuit. The contact expansion module is driven by a base unit (e.
g. emergency stop relay).
}
Functional procedure after closing the safety contacts of the base unit:
}
Functional procedure after opening the safety contacts of the base unit:

Installation

}
The unit should be installed in a control cabinet with a protection type of at least IP54.
}
Use the notch on the rear of the unit to attach it to a DIN rail.
}
Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing ele­
ment (e.g. retaining bracket or an end angle).
Operating Manual PZE X4VP
1003202­EN­08
A1 A2
=
Input
=
Power
The supply voltage is present at the input (A1) of the contact expansion module.
Close the safety contacts 17­18, 27­28, 37­38 and 47­48.
The LEDs "CH. 1" and "CH. 2" are lit.
There is not supply voltage at input (A1) of the contact expansion module.
Safety contacts 17­18, 27­28, 37­38 and 47­48 open after the delay time.
The LEDs "CH. 1" and "CH. 2" go out.
*
Y1
17 27 37
47
K1
K2
Y2
18 28 38
48
A1
17
27
37
P1
PNOZ X4VP 3s
PZE X4VP
CH.1
CH.2
17
27
37
47
18
28
38
48
P2
Y1 Y2 47
48
P1
A2
18
28
38
6