Pilz PZE X4VP8 Operating Manual
Pilz PZE X4VP8 Operating Manual

Pilz PZE X4VP8 Operating Manual

Hide thumbs Also See for PZE X4VP8:

Advertisement

Quick Links

PZE X4VP8
}
Safety relays
Operating Manual-1003206-EN-10

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PZE X4VP8 and is the answer not in the manual?

Questions and answers

Summary of Contents for Pilz PZE X4VP8

  • Page 1 PZE X4VP8 Safety relays Operating Manual-1003206-EN-10...
  • Page 2 Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user's internal purposes. Suggestions and comments for improving this documenta- tion will be gratefully received.
  • Page 3: Table Of Contents

    ........................Faults – Interference ......................Dimensions in mm ......................... Technical details ........................Safety characteristic data ......................Supplementary data ......................Service life graph ........................Remove plug-in terminals ..................... Order reference ........................EC declaration of conformity ....................Operating Manual PZE X4VP8 1003206-EN-10...
  • Page 4: Introduction

    PZE X4VP8 Introduction Validity of documentation This documentation is valid for the product PZE X4VP8. It is valid until new documentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
  • Page 5: Safety

    Safety Intended use The contact expansion module PZE X4VP8 meets the requirements of EN 60947-5-1 and EN 60204- 1. It is an expansion module for increasing the number of contacts available on a base unit. Base units are all safety relays with feedback loop.
  • Page 6: Warranty And Liability

    Note for overvoltage category III: If voltages higher than low voltage (>50 VAC or >120 VDC) are present on the unit, connected control elements and sensors must have a rated insulation voltage of at least 250 V. Operating Manual PZE X4VP8 1003206-EN-10...
  • Page 7: Unit Features

    Earth fault in the input circuit: The output relays de-energise and the safety contacts open. Block diagram/terminal configuration Delay *Insulation between the non-marked area and the relay contacts: Basic insulation (over- voltage category III), Protective separation (overvoltage category II) Operating Manual PZE X4VP8 1003206-EN-10...
  • Page 8: Function Description

    PZE X4VP8 Function description The contact expansion module PZE X4VP8 is an add-on device with selectable delay-on de-energisation, and it is used to expand a safety circuit. The contact expansion module is driven by a base unit (e. g. emergency stop relay).
  • Page 9: Preparing For Operation

    Dual-channel Base unit: 24 V DC Safety relay PNOZ X Driven via safety contacts Feedback loop Base unit: Safety relay PNOZ X Y1 and Y2 are inputs on the base unit; they evaluate the feedback loop Operating Manual PZE X4VP8 1003206-EN-10...
  • Page 10: Operation

    The safety functions may only be checked by qualified personnel. Status indicators LEDs indicate the status and errors during operation: LED on CH.1 Safety contacts of channel 1 are closed. CH.2 Safety contacts of channel 2 are closed. Operating Manual PZE X4VP8 | 10 1003206-EN-10...
  • Page 11: Faults - Interference

    2,5 W Residual ripple DC 20 % 20 % Duty cycle 100 % 100 % Max. inrush current impulse Current pulse, A1 1,7 A 1,7 A Pulse duration, A1 280 ms 280 ms Operating Manual PZE X4VP8 | 11 1003206-EN-10...
  • Page 12 With current Voltage 24 V DC Resistive 24 V DC Resistive With current Pilot Duty B300, R300 B300, R300 External contact fuse protection, safety contacts In accordance with the standard EN 60947-5-1 EN 60947-5-1 Operating Manual PZE X4VP8 | 12 1003206-EN-10...
  • Page 13 Pollution degree Rated insulation voltage 250 V 250 V Rated impulse withstand voltage 4 kV 4 kV Protection type Housing IP40 IP40 Terminals IP20 IP20 Mounting area (e.g. control cab- inet) IP54 IP54 Operating Manual PZE X4VP8 | 13 1003206-EN-10...
  • Page 14 8 mm Dimensions Height 94 mm 101 mm Width 45 mm 45 mm Depth 121 mm 121 mm Weight 320 g 320 g Where standards are undated, the 2020-07 latest editions shall apply. Operating Manual PZE X4VP8 | 14 1003206-EN-10...
  • Page 15: Safety Characteristic Data

    A safety function's SIL/PL values are not identical to the SIL/PL values of the units that are used and may be different. We recommend that you use the PAScal software tool to calculate the safety function's SIL/PL values. Operating Manual PZE X4VP8 | 15 1003206-EN-10...
  • Page 16: Supplementary Data

    To increase the service life, sufficient spark suppression must be provided on all output contacts. With capacitive loads, any power surges that occur must be noted. With DC con- tactors, use flywheel diodes for spark suppression. Operating Manual PZE X4VP8 | 16 1003206-EN-10...
  • Page 17: Remove Plug-In Terminals

    European Parliament and of the Council. The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/downloads. Authorised representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ostfildern, Germany Operating Manual PZE X4VP8...
  • Page 18 We are represented internationally. Please refer to our homepage www.pilz.com for further details or contact our headquarters. Headquarters: Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com, Internet: www.pilz.com...

Table of Contents