Table of burner and nozzle specifications

Table 1
Burner
Diameter
(mm)
Fast
100
(Large)(R)
Semi Fast
75
(Medium)(S)
Auxiliary
55
(Small)(A)
Nominal (mbar)
Supply
Minimum (mbar)
Pressures
Maximum (mbar)
*
At 15°C 1013 mbar-dry gas
**
Propane P.C.S. = 50,37 MJ/Kg
S S S
KNJ1G17A/RU
Thermal Power
By Pass
kW (p.c.s.*)
1/100
Nominal Reduced
(mm)
3.00
0.70
41
1.90
0.40
30
1.00
0.40
30
***
Butane P.C.S. = 49,47 MJ/Kg
Natural P.C.S. = 37,78 MJ/m³
S S S
KN1M117SA/RU
Liquid Gas
Nozzle
Flow*
Nozzle
1/100
g/h
1/100
(mm)
***
**
(mm)
86
218
214
116
70
138
136
103
50
73
71
79
28-30
37
20
25
35
45

TECHNICAL DATA

Oven dimensions
34x38x39 cm
(HxWxD)
Volume
50 l
Useful
measurements
width 42 cm
relating to the
depth 44 cm
oven
height 23 cm
compartment
Power supply
voltage and
see data plate
frequency
may be adapted for use with any
type of gas shown on the data
plate, which is located inside the
Burners
flap or, after the oven compartment
has been opened, on the left-hand
wall inside the oven.
Electric Plate
Standard Ø 145 mm: 1500 W
Directive 2002/40/EC on the label
of electric ovens. Standard EN
50304
ENERGY LABEL
Declared energy consumption for
Natural convection Class – heating
mode:
EC Directives: 2006/95/EC dated
12/12/06 (Low Voltage) and
subsequent amendments -
2004/108/EC dated 15/12/04
(Electromagnetic Compatibility) and
subsequent amendments -
2009/142/EC dated 30/11/09 (Gas)
and subsequent amendments -
2002/96/EC.
1275/2008 Stand-by/ Off mode
Data plate, is located inside the flap or, after the
ovencompartment has been opened, on the left-hand
wall inside the oven.
Natural Gas
Flow*
Nozzle
Flow*
l/h
1/100
l/h
(mm)
286
143
286
181
118
181
95
80
95
20
13
17
6,5
25
18
Static
21
GB

Advertisement

Table of Contents
loading

This manual is also suitable for:

Knj1g17/ru sKn1m117sa/ruKnj1g17a/ru

Table of Contents