STODDART Culinaire CR.CWCF.U.GSF Specification, Installation And Operation Manual

STODDART Culinaire CR.CWCF.U.GSF Specification, Installation And Operation Manual

Refrigerated well - counterline (under bench & drop-in)

Advertisement

Quick Links

SPECIFICATION, INSTALLATION
AND OPERATION MANUAL
READ ALL INSTRUCTIONS BEFORE USE
REFRIGERATED WELL - COUNTERLINE
(UNDER BENCH & DROP-IN)
Models:
CR.CWCF.U.GSF, CR.CWCF.U.GSB
CR.CWCF.D.GSF, CR.CWCF.D.GSB
A guide on the use, care and maintenance
of your quality Culinaire product
Revision: 02 - 8/03/2021 - A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Culinaire CR.CWCF.U.GSF and is the answer not in the manual?

Questions and answers

Summary of Contents for STODDART Culinaire CR.CWCF.U.GSF

  • Page 1 SPECIFICATION, INSTALLATION AND OPERATION MANUAL READ ALL INSTRUCTIONS BEFORE USE REFRIGERATED WELL - COUNTERLINE (UNDER BENCH & DROP-IN) Models: CR.CWCF.U.GSF, CR.CWCF.U.GSB CR.CWCF.D.GSF, CR.CWCF.D.GSB A guide on the use, care and maintenance of your quality Culinaire product Revision: 02 - 8/03/2021 - A...
  • Page 2 Page Intentionally Left Blank Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 1...
  • Page 3 Temperature Adjustment � � � � � � � � � � � � � � � � � � � 13 Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 2...
  • Page 4: Your New Culinaire Product

    Culinaire product in accordance with these instructions, will provide many years of reliable service� Stoddart is a wholly Australian owned company, which manufactures and/or distributes a comprehensive range of food service equipment for kitchens, food preparation and presentation� Stoddart products are manufactured and/or engineered in Australia to provide excellent results whilst offering value-for-money, ease-of-use and reliability�...
  • Page 5: Warranty And Registration

    The manufacturer declines any liability for damages to persons and/or things due to an improper/wrong and/or unreasonable use of the machine • Only specifi cally trained/qualifi ed Technicians (Stoddart, one of our service agents, or a similarly qualifi ed persons) should carry out any and all repairs, maintenance and services Due to continuous product research and development, the information contained herein is subject to change without notice.
  • Page 6: Installation

    = Flat Glass Gantry - Black Painted Centre Section - Adhesive Fixed = Number of Modules Sneeze Guard Control Panel Drain Spigot Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 5...
  • Page 7 Please consult national and local standards to ensure that your unit is positioned in accordance with any existing requirement Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 6...
  • Page 8: Plumbing Connections

    The TUA or TUAE TX valve is supplied with the unit� Check the specification manual for more information • Ensure the TX valve is working properly before use Refrigerant • This unit designed for R134A refrigerant� Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 7...
  • Page 9: Specification

    Note these ‘Classifi cations” should not be confused with Cabinet “Types” used for MEPS registration e.g. HC1-6, VC1-4, YC1-4 or HF1-6, VF1-4 or YF1-4 Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 8...
  • Page 10: Technical Specifications

    2522 - 7 Module 2182 - 6 Module 1842 - 5 Module 1502 - 4 Module 1162 - 3 Module Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 9...
  • Page 11 2557 - 7 Module 2217 - 6 Module 1877 - 5 Module 1537 - 4 Module 1197 - 3 Module Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 10...
  • Page 12: Control Panel

    Items, other than the gastronorm pans, should NOT be placed on the dividers� • Ensure no items are stored around the service compartment or are covering the ventilation slots� Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 11...
  • Page 13: Defrost Cycle

    The defrost cycle terminates when the temperature of the evaporator coil rises to 6°C or after 30 minutes� Products will remain refrigerated during defrost cycle if the doors remain closed • For changing of defrost cycle settings, contact Stoddart or an approved service technician After Service - Information •...
  • Page 14: Temperature Adjustment

    4. To memorise the new set point value push the key again or wait 10 seconds Note: To enter in programming mode. (Contact the Stoddart Service Department) Due to continuous product research and development, the information contained herein is subject to change without notice.
  • Page 15: Cleaning And Maintenance

    fi ne particles of Cold surfaces can burn DO NOT touch food, deeming the surface not these surfaces FOOD SAFE Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 14...
  • Page 16: External Surfaces

    Using a clean sanitised cloth, thoroughly wipe the stainless steel and metal parts dry� Do NOT let water pool on the unit� Check crevices and folds Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 15...
  • Page 17: Troubleshooting

    • If any faults/issues occur with the unit, follow the below troubleshooting procedures • If the troubleshooting procedures do not correct the problem, contact the Stoddart Service Department WARNING Technician tasks are only to be completed by qualified service people. Check faults before calling service technician.
  • Page 18 (if available)� Dispose of packaging in accordance to applicable legal regulations� Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 17...
  • Page 19 Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 18...
  • Page 20 Australia Service / Spare Parts Sales Tel: 1300 307 289 Tel: 1300 79 1954 Email: service@stoddart.com.au Email: sales@stoddart.com.au Email: spares@stoddart.com.au Service Request www.stoddart.com.au Australian Business Number: 16009690251 New Zealand Service / Spare Parts Sales / Spare Parts Tel: 0800 935 714 Tel: 0800 79 1954 Email: service@stoddart.co.nz...

Table of Contents