Page 2
Installation, Operation & Maintenance Halton MobiChef Filtration Unit Mechanical double stage pre-filtration – KSA cyclonic filters & mesh filters (>95% at 10um) Additional disposable pre-filter (EU5, F5 class) to ensure high efficient pre-filtration Compact cleanable ESP filter – elimination of fine particles Absolute filter –...
Page 3
Installation, Operation & Maintenance Halton MobiChef Halton MobiChef ‐ Preliminary Filter Maintenance Schedule Units per Units per Year, Units per Units in Filter type Year, Light Medium Year, Heavy Mobichef Wash Daily Wash Daily Wash Daily KSA & Mesh Pre Filter EAF Electronic Air Filter...
Page 4
Installation, Operation & Maintenance Halton MobiChef Cleaning Instructions: To ensure ongoing performance, the Halton Mobichef needs to be cleaned regularly. WARNING! Ensure that the unit’s power supply has been turned off before starting any maintenance operation. Ensure the cooking equipment is turned off and has sufficiently cooled down before starting any cleaning operation.
Page 5
Installation, Operation & Maintenance Halton MobiChef IMPORTANT Check the dishwasher owner’s manual. Some manufacturers do not recommend washing electronic cells in their dishwashers. If the dishwasher has upper and lower arms, position the cells carefully to allow good water circulation.
Page 6
Installation, Operation & Maintenance Halton MobiChef Washing the Cells in a Container CAUTION: Hazardous chemical can cause personal injury. Do not splash the detergent solution in eyes. Wear rubber gloves to avoid prolonged detergent contact with skin. ...
Page 7
Installation, Operation & Maintenance Halton MobiChef Reinstall the Cells and Prefilter 1. Inspect the cells for broken ionizer wires and bent collector plates. Repair as necessary or take to a Honeywell Authorized Air Cleaner Repair Station. 2. Slide the prefilter into the upstream prefilter guides.
Page 8
For Halton's national sales & support network, contact Stoddart www.stoddart.com.au Brisbane Head Office 39 Forest Way Karawatha, QLD 4117 Tel: 07 3440 7600 Fax: 07 3344 1000 email: fsehoods@stoddart.com.au Sydney Office 60 Owen St Glendenning NSW 2761 Tel: 02 8832 4399 Fax: 02 8832 4355 email: fsehoods@stoddart.com.au...
Need help?
Do you have a question about the Halton Mobichef and is the answer not in the manual?
Questions and answers
How can we reset the alarm for Carbon filter alarm? we can alrready with the brand new filter but still alarm is present. Mobichef halton is our model