STODDART GIORIK 700 Series Installation, Operation & Maintenance Manual

STODDART GIORIK 700 Series Installation, Operation & Maintenance Manual

Boiling pan electric
Hide thumbs Also See for GIORIK 700 Series:

Advertisement

Quick Links

INSTALLATION / OPERATION / MAINTENANCE
MANUAL
(READ ALL INSTRUCTIONS BEFORE USE)
700/900
BOILING PAN
(Electric)
Models:
700 Series:
PEI705T
900 Series:
PEI910T / PEI915T
Revision: A - 21/02/2023 - 02

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GIORIK 700 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for STODDART GIORIK 700 Series

  • Page 1 INSTALLATION / OPERATION / MAINTENANCE MANUAL (READ ALL INSTRUCTIONS BEFORE USE) 700/900 BOILING PAN (Electric) Models: 700 Series: PEI705T 900 Series: PEI910T / PEI915T Revision: A - 21/02/2023 - 02...
  • Page 2 Page Intentionally Left Blank Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 1...
  • Page 3: Specification

    3.3 Plumbing Connections ....12 3.3.1 Information 3.3.2 Reverse Osmosis 3.3.3 Waste Connection Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 2...
  • Page 4 Giorik product in accordance with these instructions, will provide many years of reliable service. Stoddart is a wholly Australian owned company, which manufactures and/or distributes a comprehensive range of food service equipment for kitchens, food preparation and presentation. Stoddart products are manufactured and engineered to provide excellent results whilst offering value-for-money, ease-of-use and reliability.
  • Page 5: Warranty And Registration

    1.2.1 Warranty Period All Stoddart manufactured and distributed products are covered by Stoddart’s standard Australia and New Zealand Product Warranty (minimum 12 month on-site parts and labour, terms and conditions apply). Further to this standard warranty, certain products have access to an extended warranty.
  • Page 6: General Precautions

    The manufacturer declines any liability for damages to persons and/or things due to an improper/wrong and/or unreasonable use of the machine • Only specifi cally trained/qualifi ed Technicians (Stoddart, one of our service agents, or a similarly qualifi ed persons) should carry out any and all repairs, maintenance and services 1.3.1 General Warnings •...
  • Page 7 For further information on the recycling of this product, contact the local dealer/agent or the local body responsible for waste disposal Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 6...
  • Page 8 415VAC / 50Hz / 22.7kW 415VAC / 50Hz / 22.7kW 2.1.3 Rating Plate - Check Before Installation The rating plate contains identification and technical data. See example below. Imported by: STODDART www.stoddart.com.au Description: Giorik;900 Boiling Pan; Elec; 100 Ltr Electric Rating...
  • Page 9: Technical Drawing

    415VAC / 50Hz / 22.7kW Legend Electrical Connection Cold Water Connection 1/2’’ BSP Filtered Water Connection 1/2’’ BSP Drain Connection Ø38mm Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 8...
  • Page 10 415VAC / 50Hz / 22.7kW Legend Electrical Connection Cold Water Connection 1/2’’ BSP Filtered Water Connection 1/2’’ BSP Drain Connection Ø38mm Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 9...
  • Page 11: Installation

    Please consult national and local standards to ensure that your unit is positioned in accordance with any existing requirement Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 10...
  • Page 12 DO NOT pass the power cable near or allow it to come into contact with the rear of the appliance and/or flue of the cooker Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 11...
  • Page 13: Plumbing Connections

    3.3.3 Waste Connection This unit must be drained to a tundish. Pipes must be able to resist temperatures up to 100°C Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 12...
  • Page 14: Electric Operation

    Safety Valve Pressure Gauge Steam Vent Valve Spout Tap Dial 1 (LHS) Dial 2 (RHS) Drain Valve Level Tap Fig.4. Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 13...
  • Page 15: Controller Configuration

    If an excessive amount of steam is coming out of the vent valve, the power must be reduced by adjusting the position of the right dial to the lowest numbers, or by selecting half power (pos.2) with the left dial. Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 14...
  • Page 16: Cleaning And Maintenance

    FOOD SAFE Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 15...
  • Page 17 Remove all food and pans from the unit before descaling Ensure the unit is rinsed and thoroughly cleaned after descaling Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 16...
  • Page 18: Periodic Maintenance

    12 Months 5.2.3 Troubleshooting • If any faults/issues occur with the unit, follow the below troubleshooting procedures • If the troubleshooting procedures do not correct the problem, contact the Stoddart Service Department Problem Possible Causes Possible Corrective Action ELECTRIC MODELS...
  • Page 19 700/900 Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 18...
  • Page 20 Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 19...
  • Page 21 Australia Service / Spare Parts Sales Tel: 1300 307 289 Tel: 1300 79 1954 Email: service@stoddart.com.au Email: sales@stoddart.com.au Email: spares@stoddart.com.au Service Request www.stoddart.com.au Australian Business Number: 16009690251 New Zealand Service / Spare Parts Sales Tel: 0800 935 714 Tel: 0800 79 1954 Email: service@stoddart.co.nz...

Table of Contents