FAILURE MODE FLOW CHART
Element does not heat
Remove the cook-top main PCB harness
and pull the PCB forward from the PCB case
Inspect the Main PCB
Wide pattern(Live part) blown out
Normal?
Yes
Replace the Main PCB
OK?
END
• Be sure to disconnect power before servicing.
• Wear gloves while servicing.
LGE Internal Use Only
No
Can PCB be repaired in
the cook-top element or harness
CAUTION
Yes
the field easily?
No
Check and replace
- 75 -
Repair and fix