Download Print this page

Service; Parts - Sears 390.305000 Owner's Manual

Craftsman submersible sump pump

Advertisement

General
Risk of electric shock. When servicing
pump always disconnect power to electrical outlet
and remove pump electric cord from outlet.
1. If pump does not operate:
a. Check for loose plug at electric outlet.
b. Check for blown fuses or tripped circuit breakers at
fuse box/circuit breaker box.
c. Be sure nothing interferes with action of automatic
float switch.
d. If a, b, and c above check OK, plug in a light that you
know works. If it lights, take your pump to Sears for
service. If it doesn't light, the electrical circuit is faulty;
consult a licensed electrician.
2. Pump starts, but blows fuses/trips circuit breakers:
After disconnecting power to pump, remove the screen
and shield from the bottom of the pump and make sure
that the impeller turns freely. Remove any debris ob-
structing impeller. If pump still does not operate cor-
rectly, return it to your nearest Sears Service Department
for repairs.
3. Pump runs, but does not empty sump:
a. Clean pump intake screen.
b. Water may be entering sump faster than the pump can
discharge it.
c. Be sure vertical distance from pump discharge outlet
to discharge pipe outlet is 25 feet (7.6M) or less.
d. Be sure discharge pipe is not plugged or frozen.
PERFORMANCE
Vertical Pumping Distance
5 FT.
10 FT.
GPM
61
Vertical Pumping Distance
1,5M
3,0M
LPM
230
Maximum Load Amps: 7.6 Amps.
SWITCH REPLACEMENT
NOTICE: Float must be able to swing through its complete
arc without interference from sidewall of sump, plumbing
or any other object.
1. Remove pump power cord from switch plug.
2. Remove tether clamp screw and slide cord from clamp.
3. Insert new cord in tether clamp. Put the clamp at the
same distance from the float that it was on the old switch.
4. Tighten tether clamp screw.
5. Check sump pump operation by filling sump with water
and observing operation through one complete cycle.
Failure to check installation with water
in sump can lead to improper operation, premature
pump failure and flooding.
SERVICE / REPAIR PARTS
15 FT.
20 FT.
56
50
43
4,5M
6,0M
212
189
162
SEARS 1/2 HP Submersible Sump Pump
Model 390.305000 EXPLODED VIEW
25 FT.
1469 0195
33
Key
Part
7,6M
No.
Number
1
PS17-68
125
2
U30-955SS
3
CC0030-13
4
PS1-28P
5
U30-920SS
6
PS5-22P
7
PS20-19
8
PS3-29P
9
U30-934ZP
F642-0391
• Not Shown.
NOTE: If motor fails, replace entire pump.
To Order Parts in the U.S.A., Call
Sears Product Service, 1-800-366-7278
To Order Parts outside the U.S.A., Call
Your local Sears Service Center or Store
5
Float Switch
Float Switch
P/N PS217-62
P/N PS217-62
1
Power Cord
Power Cord
P/N PS17-54
P/N PS17-54
2
3
Pump will have either Y-Cord arrangement (item 5)
Pump will have either Y-Cord
or Power Cord / Switch arrangement as shown
arrangement (Key No. 1) or
above.
Power Cord/Switch arrangement
See Note
See
as shown here.
Note
4
5
6
7
8
9
REPAIR PARTS LIST
Part
Description
Cord and Switch
#8 x 5/8" Type A Screw
Clamp
Volute
#10 - 16 x 7/8" Screw (3 req'd).
Impeller
Volute Gasket
Volute Plate
#8 x 5/8" Type A Screw (8 req'd.)
Owner's Manual
Quantity ONE unless otherwise noted ( ).
283 1093A

Advertisement

loading