Vanair Manufacturing, Inc. recommends that
the following procedure is used for routine
shutdowns in order to keep the system in
optimal condition and minimimize undue
stress that may occur during the next start up
session if some of the machine conditions
were left in working mode(s) or had auxiliary
power draws left intact (such as a tool
receptacle left plugged into the generator,
etc.).
To prepare the machine for shutdown:
1. Shut off any tools or other items
that are drawing power from the
generator or compressed air from
the air tank.
2. Close all service valves.
3. Unplug any power cords that are
plugged into the generator panel.
4. Turn the Generator and Welder
switches on the control panel
(Figure 4-2, [B & G]) to their OFF
positions.
5. Allow machine to run at idle for a 3-
5 minutes to allow for a cool down
sequence.
6. Turn the Engine Control Switch to
the OFF position [A
leaks are present, the engine
TABLE 4A: ENGINE THROTTLE CONTROL FUNCTION CONDITIONS
Pressure Setting
Tank Pressure Below (<)
100 PSI or Set Pressure
Tank Pressure Above (>)
100 PSI or Set Pressure
I
Any combination of the 150 Power System output functions (compressor, generator, welder) used simultaneously at
capacity will have an adverse affect on engine running at full throttle.
II
Factory set pressure: 95 PSI = ON / 125 PSI = OFF
Vanair Manufacturing, Inc.
vanair.com • 800-526-8817
]. If no air
1
Generator
Welder Switch
Switch
OFF
II
OFF
II
OFF
ON
ON
090051-OP_r0 (FEB-2014)
Refer to Engine Owner's Manual for
additional information pertaining to the
4.3 ENGINE THROTTLE
CONTROL FUNCTIONS
The engine speed is controlled by three
factors:
1. The level of air pressure in the tank
2. The position of the welder switch on
3. The position of the generator switch
Consult Table 4A: Engine Throttle Control
Function Conditions to understand how the
engine speed relates to the demand(s) of the
machine system's output functions.
I
Engine Speed Condition Result
OFF
Engine runs at full throttle.
OFF
Engine runs at idle speed, ready for application.
ON
Welder can be activated by striking an arc (with engine
running at full throttle) and depressing button on
electrode holder.
OFF
Engine runs at full throttle speed (3600 RPM);
generator is ready for use.
ON
Full speed and all items available for use.
SECTION 4: OPERATION
should start at idle speed the next
time it is started.
NOTE
starting of the engine.
and the position of the pilot valve
adjustment switch (refer to Figure
4-3).
the unit control panel, and the use
of the welder.
on the control panel.